Care And Cleaning - K2 Pumps SWW05002TPK Notice D'utilisation

Pompes de manutention solides et submersibles
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Fuse Data
MODEL
SWW05002TPK/SWW05002VPK
SWW07503TPK
SWW05001TPK/SWW05001VPK
SWW07501TPK/SWW07501VPK
OPERATION
WARNING: Do not handle this pump or plug in or unplug this pump with wet hands or while standing in water, unless you
are certain all power has been turned off to the pump. Remember, the pump should be connected only to a properly
grounded, GFCI outlet.
1. Make certain the pump is submerged in water. Running the pump dry can damage the shaft seal.
2. Plug the pump power cord plug into the back of the float switch cord's plug. Plug the float switch cord plug into a
115V GFCI power outlet.
3. After connecting power to the pump, test the pump:
a. Fill the basin to above the float switch operation ON Height. The pump should start pumping.
b. The pump should pump the water down to below its float switch operation OFF Height and then stop pumping.
c. If the water drains back into the basin and restarts the pump, make sure the check valve is properly installed
and working. Also make sure that all pipe connections are tight.
4. The motor is equipped with an automatically resetting thermal overload protector. If the motor gets too hot, the
overload protector will shut off the pump before it is damaged. When the motor has cooled sufficiently, the overload
protector will reset, and the motor will restart.
NOTICE: If the overload protector stops the pump repeatedly, disconnect the power from the pump and check to find the
problem. Low voltage, a long extension cord, clogged impeller, screen blocked by debris, or water that is too hot can
cause motor overheating.

CARE AND CLEANING

CAUTION: Always use the handle to lift the pump. Never use the power cord to lift the pump. To avoid skin burns,
unplug the pump and allow time for it to cool after periods of extended use.
Do
When the power is disconnected, inspect the
pump suction screen and remove all debris,
then plug the pump back into the grounded
(GFCI) outlet.
6
HP
Voltage
1/2
115
3/4
115
1/2
115
3/4
115
Do Not
Do not disassemble the motor housing. This motor
has NO repairable internal parts, and disassembly
may cause leakage or dangerous electrical wiring
issues.
Do not lift up the pump by the power cord.
For Professional Technical Support call 1-844-242-2475
Individual Branch
Circuit Required
(Amps)
15
20
20
20