Installation Of Outdoor Unit - LG ATUW18GPLS1 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION OF OUTDOOR UNIT

Installation Places
- If an awning is built over the unit to prevent direct sunlight or rain exposure, make sure that
heat radiation from the condenser is not restricted.
- Ensure that the spaces indicated by arrows around front, back and side of the unit.
- Do not place animals and plants in the path of the warm air.
- Take the air conditioner weight into account and select a place where noise and vibration are
minimum.
- Select a place so that the warm air and noise from the air conditioner do not disturb neighbors.
Piping length and the elevation
Free Joint Single Outdoor
MODEL
ATUW18GPLS1
Ø12.7(1/2)
ABUW18GM1S1
Ø12.7(1/2)
ATUW48LMLS1
Ø19.05(3/4)
ATUW54LMLS1
Ø19.05(3/4)
ABUW48LM3S1
Ø19.05(3/4)
ABUW54LM3S1
Ø19.05(3/4)
APUW48LT3S1
Ø19.05(3/4)
If installed tube is shorter than Standard length, additional charging is not necessary.
Additional Refrigerant = (Max. Length - Standard Length) x Additional refrigerant (g)
More than
300 mm
F e
n c e
o b
o r
s t a
c l e
s
Pipe Size
Gas
Liquid
Standard
Ø6.35(1/4)
Ø6.35(1/4)
Ø9.52(3/8)
Ø9.52(3/8)
Ø9.52(3/8)
Ø9.52(3/8)
Ø9.52(3/8)
Indoor unit
A
B
Outdoor unit
INSTALLATION OF OUTDOOR UNIT
More than
More than
More than
300mm
300mm
300 mm
More than 600 mm
More than 700 mm
Length A (m)
Elevation B (m)
Max.
Standard
7.5
25
5
7.5
25
5
7.5
50
5
7.5
50
5
7.5
50
5
7.5
50
5
7.5
50
5
Outdoor unit
A
Indoor unit
B
Unit : mm
Additional
Refrigerant (g/m)
Max.
15
20
15
20
30
40
30
40
30
40
30
40
30
40
7

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Abuw18gm1s1Abuw54lm3s1Abuw48lm3s1Atuw54lmls1

Table des Matières