start after a number of attempts, abort the process and investigate the cause of the defect.
Removing the power pack
Rotate the On/Off switch for the starter aid and the selection switch for starter aid voltage to the OFF setting. First
disconnect the black (-) pole calliper, coil the cable and attach the pole calliper to the designated holder. Then
disconnect the red (+) pole calliper, coil the cable and attach the pole calliper to the designated holder. Always
maintain this sequence.
Recharge the power pack.
Use as 12 V voltage supply
The power pack can be used as a 12 V direct current source for many devices that can be operated with 12 V direct
current and a cigarette lighter plug. Plug the cigarette lighter plug of the device you wish to operate into the 12
V outlet. The device you wish to operate should not require a current greater than 10 A. The outlet of the power
pack has an automatic fuse that will deactivate the device at a current greater than 10 A. If deactivation occurs,
immediately disconnect the power pack and the operating device. After approximately three minutes, the fuse will
free the outlets for use.

Working light

The ON-OFF switch (Position 19 in the overview) is used to switch the LED working light as well as the illumination
of the pole callipers on and off.
Maintenance and care
Maintenance Store the power pack at room temperature. If the power pack is not used for a longer period of time,
it must be recharged. In winter, recharge every two months, in summer recharge every month.
Care Switch the power pack off before cleaning. Clean the housing of the power pack with a soft, dry cloth. Do
not use any aggressive cleaning agents or solvent-based cleaners. Never allow liquids to ingress into the housing.
Notes regarding environmental protection
Do not dispose of electrical devices with the household waste! Electrical and electronic scrap must be col-
lected separately and disposed of in an environmentally responsible manner for recycling. Please contact
your community or city administration regarding disposal options for electrical and electronic scrap.
You are legally obliged to return batteries and battery packs. After use, they may be returned to us, han-
ded in to a communal collection point, or to a local dealer. Batteries containing hazardous materials are
labelled with a symbol consisting of a crossed out trash can and the chemical symbol (Cd, Hg or Pb) which
designates the heavy metal responsible for the hazard.

Contact information