Fireplace Installation
above an electrical outlet.
Access to the electrical outlet
must be maintained. Ensure
the installation meets the
national and state/provincial
electrical codes.
!
NOTE: It is recommended
that the bottom of the unit not
be mounted higher than 1020
mm (40") from the Fireplace
Installation ground to maintain
an optimized viewing angle of
the flame.
CAUTION: Ensure that the
top of the unit is at least 610
mm (24") from the ceiling
or any object (i.e. Electrical
receptacles) that may obstruct
or be susceptible the flow or
temperature of air out of the
unit.
CAUTION: High temperature,
keep electrical cords, drapery,
and other furnishings at least
3 feet (0.9 m) from the front of
the heater and away from the
side and rear.
2. The wall-mounting bracket
must be mounted into at
least two (2) wall studs.
Studs should be accessed
through two (2) wall-bracket
holes in one of the following
Figure 2
610 mm (24 in)
MINIMUM
40 in (1020 mm)
RECOMMENDED
Figure 3
combinations: A&F, B&D, or
C&E (Figure 2).
!
NOTE: Wall anchors must
be installed in the appropriate
wall locations to fasten the wall
bracket through the remaining
holes (Figure 3). For example, if
you plan to secure the bracket to
studs through holes A&D, install
anchors centered on holes B & C.
3. Hold the wall-mounting
bracket on the wall and mark
the location of ONE (1) of the
9