dorma MUTO COMFORT L 80 Notice De Pose page 4

Masquer les pouces Voir aussi pour MUTO COMFORT L 80:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 8
MUTO COMFORT
LAMINATED SAFETY GLASS
About this manual
This manual describes the modification and installation of a
roller carriage for the MUTO Comfort sliding door systems in
connection with laminated safety glass (LSG).
The installation will be illustrated using the example of a
MUTO Comfort XL 150 roller carriage. This procedure also ap-
plies for the roller carriages of all other systems for which LSG
(laminated safety glass) can be used.
Target group
Installation by Dorma authorized professionals only.
Intended use
- for sliding doors in dry indoor areas only
- for slow manual opening and closing only
Requirements for glass door wing
- Laminated safety glass (LSG in accordance with EN ISO
12543-1)
Safety instructions
- The installation must be carried out by two people
- Wear protective clothing
Symbols used in this manual
NOTE

A note is used to draw attention
to important information.
Cleaning the glass surfaces.
Use only silicone-free and oil-free cleaners
(e.g. acetone).
Follow written instructions
1 2
Installation sequence
A
Individual steps within an installation step
1
2
Maintenance, care, repair
- at least 5 years of maintenance-free
operation (at 50 activations per day)
- immediately replace damaged parts
- use only original DORMA parts
Disposal
Dispose properly in accordance with the applicable national
regulations.
4
DORMA
TRANSLATION OF THE ORIGINAL MANUAL
CAREFULLY READ THE MANUAL BEFORE USE
KEEP IT FOR LATER CONSULTATION
General instructions
- Note the desired opening direction and install the roller
carriages accordingly.
- Check the glass for defects and damage before installation.
- Clean the glass surfaces before installing the roller car-
riages. Use only silicone-free and
oil-free cleaners.
Instructions for the following installation steps
4
5
6
8
9
10
 Please follow the enclosed installation manual for
Please follow the enclosed installation manual for
your MUTO sliding door system when engaging the
roller carriages.
Limited processing time of 3 minutes at a room
temperature of ca. 23 °C.
- INNOTEC ® Repaplast
Observe the safety data sheet, technical
information, and processing instructions
of the adhesive manufacturer!
- Remove any mixing tube contents before use
in order to avoid impurities in the mixture and to
ensure optimal adhesive hardening
(disposal according to safety data sheet).
2 Stop the injection as soon as the adhesive
comes out from the edges. Do not remove this until
after the hardening period (see
2 Stop the injection as soon as the adhesive
comes out from the edges. Do not remove this until
after the hardening period (see
1
Let the adhesive harden.
The hardening period until readiness for
installation is 15 minutes at a room
temperature of ca. 23 °C.
2
After 15 minutes have passed carefully remove
the hardened adhesive.
1
Apply the sticker visibly on the door stating
that the door may only be carefully moved
in the first 24 hours.
It will be ready for installation after 45
minutes. Do not expose the roller carriages to
any sudden loads during this time.
your MUTO sliding door system for the further instal-
lation of the door.
EN
9
).
9
).

Publicité

Table des Matières
loading

Table des Matières