Electrical Connection

The storage heater is connected to element feed
(OFF-PEAK Tariff) and control cables for the room
thermostat and the charge control (A1/Z1; A2/Z2).
You will find the number and type of storage brick
packs in the section "Technical Data" The heater is
suitable for a direct cable feed, it is also suitable for
feeding from a spur junction.
According to regulations every branch circuit must be
individually protected, for instance by circuit breakers
for all phases. These circuit breakers must have con-
tact openings of at least 3mm.
Each storage heater must be connected to its own
separate load-current cable from the distributor panel.
Running cables from heater to heater is not allowed.
According to Utility Regulations, a single-phase con-
nection is only allowed for a heater rating of up to 2
kW. To do this, bridge the terminals L1-L2- and L3.
To connect to a Central Charge Control with "single-
wire control", bridge terminals A2/Z2 and N
Make sure the earth cable is firmly connected.

Cable feed

All manuals and user guides at all-guides.com

Utility release relay

The Utility release relay on the distributor panel may
be omitted if this does not violate the local Utility regu-
lations. The thermal relay (K1) installed in each Su-
perflat heater may be used as an Utility release relay.
For this, lead the release signal LF (230V 50Hz) from
the ripple control receiver, utility clock relay or other
clock meter into the connection chamber of each Su-
perflat heater and connect it to terminal „SH". Further
on, detach the power supply (L) of the electronic
charge control from terminal „L1" and connect it to
terminal „SH".