Setup and Commissioning
Settings can be performed before
fi tting the sensor unit. If you wish
to change the settings again
after fi tting the sensor unit, the
catch must fi rst be released with
a fl at-bladed screwdriver and the
sensor unit must be removed (see
illustration below).
www.steinel.net
(800) 852-4343
All manuals and user guides at all-guides.com
When this is done, the light
fi xture automatically switches to
continuous operation. On fi tting
the sensor unit, an approximately
45 second measuring phase is
initiated. The red LED fl ashes
during this period.
Setup and Commissioning
Light level
The light level feature allows
lighting to remain OFF
during daylight, regardless of
occupancy. Daytime operation
is at 200 footcandles (factory
setting). Nighttime operation is
at .2 footcandles. Factory setting
is 200 fc.
.2 – 200 fc
The adjusting screw must be
set to daytime operation (200
fc) when adjusting the detection
zone and performing the function
test in daylight.
Time delay
Time delay is the period of time
lights remain on after the last
detection. Adjustment ranges
from 5 seconds to 20 minutes.
Factory setting is 5 seconds.
approx. 5 sec. – 20 min.
approx. 5 sec. – 20 min.
The shortest time delay setting is
recommended when adjusting the
detection zone and performing the
function test.
www.steinel.net
(800) 852-4343
11