8
Wiring
When installing, make sure power
has been switched off at the
breaker and check that the circuit
is dead with a voltage tester.
Black - Hot
White - Neutral
2 Red - Relay
Neutral
Hot
www.steinel.net
(800) 852-4343
All manuals and user guides at all-guides.com
Standard wiring:
Connect Black and one of
the Red wires to Hot (120VAC
input)
Connect White to Neutral
Connect other Red to Load
(120VAC output)
L
O
A
D
Operation
The IS D360-120 turns lighting on
and off automatically based on
occupancy. Adding a wall switch
provides manual on/off control.
Sensor operation
• Switch light ON (when light is
OFF): Turn switch OFF and ON
once. Light stays ON for the
period selected.
• Switch light OFF (when light
is ON): Turn switch OFF and
ON once. The light turns off or
switches to sensor mode.
Manual override
• Activate manual override: Turn
switch OFF and ON twice.
The lamp is set to stay on for
4 hours (red LED lights up
behind the lens). Then it returns
automatically to sensor mode
(red LED off).
• Deactivate manual override:
Turn switch OFF and ON once.
The light goes out or switches
over to sensor mode.
Light level function
The sensors incorporate a built-in
light level sensor which keeps
lighting off during daylight hours,
regardless of occupancy.