Starting Electric Start Engines; Manual Start; Generator Shut Down - DeWalt DXGNR6500 Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

B
DXGNR 6500
B
DXGNR 8000
Slide engine choke (C) to Full Choke position (left).
5.
C
Firmly grasp recoil handle and pull slowly until increased
6.
resistance is felt. Pull rapidly up and away.
When engine starts, move choke knob to 1/2-choke position
7.
until engine runs smoothly, then fully into Run position. If
engine falters, move choke back to 1/2-choke position until
engine runs smoothly, then to Run position.
If engine fires, but does not continue to run, move choke
8.
lever to Full Choke and repeat starting instructions.
IMPORTANT: Do not overload the generator. Also, do
not overload individual panel receptacles. These outlets
are protected against overload with push-to-reset type
circuit breakers. If amperage rating of any circuit breaker
is exceeded, that breaker opens and electrical output to
that receptacle is lost. Read "Don't Overload the Genera-
tor" carefully.
Instruction Manual for Portable Generator

Starting Electric Start Engines

CAUTION
ing or stopping unit. Failure to do so could result in
equipment and property damage.
Unplug all electrical loads from the unit's receptacles before
1.
starting the engine.
Place generator on a level surface.
2.
Open the fuel shut-off valve.
3.
Move engine choke knob outward to Full Choke.
4.
Press and hold Start/Run/Stop switch in the Start position.
5.
003287
When engine starts, release the switch to the Run position.
When engine starts, move choke knob to 1/2 choke position
6.
until engine runs smoothly, then fully to RUN position. If
engine falters, move choke knob back to 1/2 choke position
until engine runs smoothly, then move to Run position.

Manual Start

The generator is equipped with a manual recoil starter
which may be used if the battery is discharged. See
Starting Pull Start Engines
NOTICE:
003606
outlets along with the included battery charger to charge
the battery while the generator is running.
To start manually:
Firmly grasp the recoil handle and pull slowly until
1.
increased resistance is felt.
Pull rapidly up and away to start engine.
2.
Follow the same choke sequence.
3.
NOTICE:
repeat starting instructions.
IMPORTANT: Do not overload generator or individual
panel receptacles. These outlets are overload protected
with push-to-reset circuit breakers. If amperage rating of
any circuit breaker is exceeded, that breaker opens and
electrical output to that receptacle is lost. Read
000209
Generator Limits

Generator Shut Down

CAUTION
ing or stopping unit. Failure to do so could result in
equipment and property damage.
Shut off all loads and unplug electrical loads from generator
1.
panel receptacles.
Let engine run at no-load for several minutes to stabilize
2.
internal temperatures of engine and generator.
Move Run/Stop switch to Stop.
3.
Close fuel valve.
4.
NOTICE:
tor bowl out of fuel. For emergencies, switch to Stop.
Equipment and property damage. Dis-
connect electrical loads prior to start-
.
The switch must be in the Run position.
Use one of the generator's receptacle
If engine fires, but does not continue to
run, move choke lever to Full Choke and
carefully.
Equipment and property damage. Dis-
connect electrical loads prior to start-
Under normal conditions, close fuel
valve and allow generator to run carbure-
Operation
Know
15

Publicité