This manual has been prepared to acquaint you with the operation and maintenance of this product. Study the
information provided carefully to avoid problems associated with improper application or maintenance. Upon receipt
of your generator, verify that it is complete and in good condition.
The generator is comprised of a 4 stroke, air-cooled engine directly coupled to a 2 pole alternator producing either
125VAC or 125/250VAC depending on model. The no-load speed is approximately 3750rpm with the speed under
load going to approximately 3600rpm thus producing a frequency of 60Hz.
INITIAL INSPECTION
Upon receiving your generator set, inspect the product to make
sure it is complete and in good condition. Handle with care and
place in a suitable site for storage or operation.
GROUND CONNECTION
The generator should be grounded to earth to reduce the risk
of electrical shock. To do this you will need a grounding rod
and an appropriately sized copper ground wire. Drive the
ground rod into the earth, connect one end of the copper wire
to the rod and connect the other end to the external ground
connection on the generator set. This is a general explanation,
consult National and Local electrical codes to ensure
compliance.
GENERATOR NEUTRAL BOND
There is a permanent conductor between the generator
(stator winding) and the frame.

BEFORE START-UP

ENGINE FUEL
Use Unleaded Gasoline with minimum Octane 86. Check the
fuel gauge and add as necessary.
SLOWLY ADD UNLEADED GASOLINE TO FUEL
TANK
DO NOT OVERFILL TANK
DO NOT FILL ABOVE TOP OF FUEL SCREEN. THIS
WILL ALLOW EXPANSION IN HOT WEATHER AND
PREVENT OVERFLOW.
ENGINE OIL
NOTICE:
DO NOT attempt to start this engine without
filling the crank case with the proper amount and type of oil.
Your generator has been shipped from the factory without oil
in the crankcase. Operating the unit without oil can damage
the engine.
The oil fill ports are located on both sides of the engine. The
gray filler cap has an integral dipstick. Add the proper amount
of oil and check the level using the dipstick.
English

OPERATION

GENERAL INFORMATION

NOTE: The dipstick should be placed into the filler opening but
not screwed in to check the level. The engine manual or other
information provided by the engine manufacturer supersedes
data provided here.
ENGINE
Honda GX270
Honda GX340
Honda GX390
Honda GX630
STARTING BATTERY (Electric Start Models Only)
The starting battery should be rated at 12V-18AH (12V-34AH
for DXGN14000). The battery is fully charged if a voltage of
13.7VDC is measured across the terminals using a DC
Voltmeter.
POSITIONING
Place the generator set on a flat and solid surface to
prevent it from sinking.
Keep fuel, oil or other flammable or combustible materials
at a safe distance from the generator set.
Select a site that is well ventilated and protected from the
weather.
Place the generator set safely away from people and
animals.
CAUSE FUEL SPILLAGE
Check the engine oil before each use. Never operate the
generator set with insufficient oil.
GENERATOR SET OVERLOAD
Do not exceed the rated load of the generator set when
operating continuously. Before connecting items to the
generator set, determine the total electrical requirements of the
products to be connected. The requirement of each item is
generally given on the manufacturer's nameplate. Following is
a list of commonly used items and typical requirements. Use
this list as a guideline only if no other data is available.
12
HP
Oil Capacity
Grade
8.5
1.16 qt (1.1 l) API SJ SAE 10W-30
10.7 1.16 qt (1.1 l) API SJ SAE 10W-30
11.7 1.16 qt (1.1 l) API SJ SAE 10W-30
20.2 2.1 qt (2.0 l)
API SJ SAE 10W-30
TILTING CAN
OPERATION