INDICATIONS ON DISPLAY
Display
START
LOAD
PELLET
FLAME
LIGHT
WORK
WORK
MODULAT
COOLING
WAITING
ECO-STOP
STAND-BY
CLEANING
BASKET
CLEANING
FINAL
HOT EXHAUST
ALARM
ACTIVATD
SAFETY DEVICES
- The appliance is equipped with different security features, which grant and assure the
regular functioning.
-Pressure switch for the control of exhaust fumes. In case of obstruction of the fume exhaust
duct, due to materials, contrary wind, or to any other difficulty that do not allow a regular
outflow of the fumes, this device signals the problem to the appliance and a stop cycle starts,
while on the display appears "FAILURE DEPRESS"and a beep will sound.
-Fume temperature control. The temperature of the exhaust fumes is constantly controlled by
a specific feeler in order to control the regular working of the appliance, in case the
temperature is exceeding the max. value (factory value setting) a cooling cycle starts,
reducing the power (HOT EXHAUST), if the temperature of the fume is still increasing a stop
cycle starts, while on the display appears "HOT EXHAUST" and a beep will sound.
-Exhaust fumes motor control. The electric motor for exhaust fumes is continuously checked
in order to verify the correct functioning and in case of anomaly, a stop cycle will start and
the display will signal "FAN LIGHTIN" and a beep will sound.
-Control of temperatures feelers. The correct working of the feelers, which ensure a correct
working of the appliance, are constantly controlled by the electronic card. If the controlled
values do not re-enter into the working parameters a stop cycle starts, while on the display
appears a message of alarm.
Appliance phase
Lighting element
heating
Initial fuel load
Fuel lighting
Working at power
Working at reduced
power
Stand-By function
activated
Stand-By function it
is activated
Automatic cleaning
cycle of burner
basket
Off
Fumes temperature too
high
Appliance in Alarm,
start of stopping
cycle
Explanations
Lighting phase started, heating of the lighting element
Fuel started to convoy to the burner basket
The appliance has noticed the presence of fire in the
basket, stabilization phase starting.
The appliance has terminated the lighting phase and is
now ready to work at the selected power.
Room temperature has reached the selected values.
Room temperature has exceeded the selected one.
Appliance switch off waiting for diminution of
temperature.
Room temperature has exceeded the selected one,
appliance first reduce the power and then switches off
Appliance carries out an automatic procedure to
eliminate part of residuals remained into the burner
Appliance started the extinction phase and proceed
with the disposal of the fuel still into the basket.
The appliance has detected a fumes temperature too
high, the power reduces automatically.
Appliance noticed an anomaly, extinction cycle starts
and the display signals the type of problem.