Microwave flow regulation
Fig. 21
It is recommended to reduce the sensitivity of the microwave in relation to the desired coverage distance.
DIP 1
DIP 2
OFF
OFF
OFF
ON
ON
OFF
ON
ON
DIP 3
DIP 4
OFF
OFF
OFF
ON
ON
OFF
ON
ON
DIP 5
DIP 6
23
DIP SWITCH SETTING
OPERATION'S LOGIC
PIR 1 AND PIR 2 AND MW
(PIR 1 OR PIR 2) AND MW
PIR 1 AND PIR 2
PIR 1 OR PIR 2 OR MW
ON
Antimask function ACTIVATED
LEDs Off
FUNCTIONAL DESCRIPTION
PIR 1 / PIR 2: HIGH sensitivity.
PIR 1 / PIR 2: MEDIUM-HIGH sensitivity.
PIR 1 / PIR 2: MEDIUM-LOW sensitivity.
PIR 1 / PIR 2: LOW sensitivity.
FUNCTIONAL DESCRIPTION
Alarm output active only when all three technologies
detect a presence.
Note: usable in most external installations.
Alarm output active when the MW and any of the two PIR
detect a presence.
Note: not recommended in particularly hostile
Alarm output active when both PIR detect presence; the
MW is not managed
Note: the detection of MW has no influence on the
performance of the detector.
Alarm output active when only one technology (one of
the two PIRs or the MW) detects a presence.
Note: not usable in external applications.
Antimask function DEACTIVATED
environments.
OFF
LEDs Always on