AL912AES POWER SUPPLY INSTRUCTIONS MANUAL
1. PRELIMINARY INFORMATIONS
Manufacturer
:
elc 59, avenue des Romains 74000 Annecy FRANCE
Phone : +33 (0)4 50 57 30 46 Fax : +33 (0)4 50 57 45 19
Instrument
:
Linear and regulated power supply
Brand
:
elc
Type
:
AL 912AES
2. DESCRIPTION
2-1 Overview
2-2 Overall view
You have just purchased elc AL 912AES linear and regulated
power supply. We thank you and congratulate you for your choice.
Practical and easy to install in electrical equipment boxes, this power
supply has very good electronical performances and will perfectly
fit to electricians and other users.
It is possible to add an optional protection cover CP 910A.
2-2 Technical features
Output voltage
: 24 V ± 0.5 %
Current
: 0.8 A permanently
Internal resistance
: < 50 mΩ
Ripple
: < 3 mV peak to peak
Regulation
: < 40 mV for a load change from 0 to 100%
: < 10 mV for a line change from ± 5% to max load.
Hold-up time
: 20 ms for charge 50% and 5 ms for 100%
Protections
: against overtemperature by thermal shutdown
against short-circuits by current limiting
against transformer primary overcurrent by fuse
Input voltage
: 400 V ± 10% 50/60 Hz
Insulation class
: I
Consumption
: 50 VA max
Electric strenght
: 5550 V
between input and output, 3200 V
AC
Insulation resistance : >100 MΩ with1000 V between output and chassis
Environmental
: of use
: + 5 °C to + 40 °C
conditions
storage
: -10 °C to + 50 °C
moisture
: see curve
Dimensions
: L = 76 mm H = 113,5 mm D without cover = 74 mm
Weight
: 0,892 Kg
Volume
: 0,53 dm
3
3. SAFETY INSTRUCTIONS
The instrument must be used according to the instructions of this manual. The instrument must
be connected to an earth connection. A bipolar switch or a circuit breaker must be included in
the electrical installation close to the instrument and must be easily accessible by the operator. In
order to avoid electric shocks, this power supply should not be accessible under normal operation
(Ex : installation in electrical equipment box or closed box...).
To increase safety, we advise you to install the optional cover CP 910A.
4. INSTRUCTIONS OF USE
2 ways of installation are possible :
- On a symmetrical DIN rail with 2 clips located backside.
- At the bottom of an electrical equipment box or in a box, thanks to oblong holes backside.
It has to be installed with 3 screws M4, the panel cut-out is given below.
Indicator
Main
connector
connector
block
beween input and earth
AC
%
8 0
D with cover = 76 mm
5 0
m a x i m u m
r e l a t i v e
m o i s t u r e
3 1
4 0
Respect the connections of the main and of the output indicated on the connector blocks in
order to avoid damages and to have an output delivering 24 V 0,8 A.
Power supply characteristics are given at the terminals of the instrument.
The use of weak section or important length wire leads to a degradation of the characteristics
main + earth
Once plugged to main, it is ready to work.
5. OPERATION
Output
AL 912AES is a linear and regulated power supply, with current limitation.
block
6. MAINTENANCE
No particular maintenance is required for this instrument.
Avoid dust, moisture, shocks : your instrument will be grateful for that.
For a higher protection, we advise you to install the optional cover CP 910A.
If the indicator does not switch on when plugging, check :
- Main voltage presence.
- Connection to main input voltage.
- Fuse 5x20 T250mA after having disconnected the main.
7. AFTER SALES SERVICE
During TWO YEARS, spare parts and workmanship are guaranteed. This guarantee does not apply to
instrument presenting defects or failures caused by an improper use. Return expenses are borne by the
client. Only devices returned with a dated purchasing invoice can be recovered by the guarantee. Any
intervention carried out by unauthorized persons or organizations, shall void the guarantee .
8. DECLARATION OF CONFORMITY
Manufacturer
:
ELC, 59 avenue des Romains 74000 Annecy FRANCE
declares the product
Name
:
Linear and regulated power supply
Type
:
AL 912AES
conformable to the requirements of the directives :
Low voltage 2014/35/UE, Electromagnetic Compatibility 2014/30/UE and RoHs 2011/65/UE.
The following harmonized standards have been applied :
Safety
: EN 61010-1:2010
° C
EMC
: EN 61000-6-2:2006, EN 61000-6-4:2007 + A1:2011
Annecy, June 21
, 2016
th
ELIMINATION OF MANUFACTURING WASTES BY THE PRIVATE USERS IN THE EU
This symbol written in the product or in its packaging indicates that this product must not be throw in
the garbage with your other waste.
Its your responsability to rid of your manufacturing wastes bringing it to a specialized sorting office
for the recycling of electrical and electronic instruments.
Collection and recycling separated of your wastes will contribute to preserve natural resources and
guarantee a recycling respectful of the Environment and human health.
For further information concerning the recycling center near your place of residence, contact your town
hall, the elimination service of garbage heap or the store where you bought the instrument.
24 V 0.8 A
H. CURRI Manager
.