INsTALLATIoN
Installation
f To prevent contaminating the wall mount casing during plas-
f
tering, use the cover included in the standard delivery.
5.1.2 Installation version 2: Fixing the wall mount casing with
PUR foam
1
1
1 Fixing holes
f Seal the fixing holes with the plugs included in the standard
f
delivery.
f Align the wall mount casing horizontally.
f
f To prevent contaminating the wall mount casing during plas-
f
tering, use the cover included in the standard delivery.
28
| LWE 40
1
1 Aperture for injecting PUR foam for fixing the wall mount
casing
Material losses
Only use rigid 2-component PUR foam.
1
f To secure the wall mount casing in position, spray a little
f
PUR foam through the plaster protection cover into the cavity
between the wall mount casing and the wall at two opposite
corners.
f Hold the wall mount casing in place until the foam has dried
f
and the wall mount casing is held securely in position.
5.1.3 Foaming
Material losses
1
Make sure that the support elements are correctly posi-
tioned in the wall mount casing.
Material losses
Only use rigid 2-component PUR foam.
Note
Observe the instructions for the PUR foam. To increase
the foam volume, you may need to moisten the substrate.
Inside
1
1
1
1
1 Apertures for foaming
The plaster protection cover has six apertures for foaming.