Installation Instructions, Only For Experts; Description - Sentiotec RS485 Instructions De Montage Et Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation instructions, only for experts

2. Description

The RS485 interface allows sauna control units in the Professional Series
(Pro-B2, Pro-B3, Pro-C2, Pro-C3) to be connected to a domestic bus system
using an RS-485 connection and a configurable protocol.
This interface documentation provides a text-based communication protocol which
allows the majority of the Professional Series functions to be controlled remotely.
For the physical connection, the sauna control units in the Professional Series
are equipped with an RJ45 socket. In addition, the Connectivity Set (item no.
Pro-CS) is required.
Scope of delivery of the Connectivity Set (item no. Pro-CS)
● Network cable 0.5 m
● RJ45 to print terminal adapter
● 120 W terminating resistor
RJ45 to print
terminal adapter
RS485
RJ45 socket
Fig. 2: Diagram
Connection of the Professional Series devices to domestic bus systems
using an RS-485 connection
1
2 GND
3
4 B
5 A
6
7 GND
8
Twisted-pair cable
1 2 3 4 5 6 7 8
Fig. 1: Terminal assignment
of the adapter
120 W terminating resistor
RS485
Gerät
p. 4/12
B
A