Programmable Functions of the Microphone Units with the MCW-D 200 Editor Software
4.8 Request-to-Talk Mode
Delegate
(7)
(8)
4.9 Zoning Function
• For interpreting applications or a separate sound reinforcement of hall and panel we recommend the Zoning function.
• With this function certain microphone units can be sent to a certain output of the optional CA 2451 PCB.
4.10 How to receive Messages
Please vote now
62
(11)
• This operating mode is only possible in conjunction with a PC using
the MCW-D Controller software or media control system (AMX/Panja
Crestron
®
etc.) or a chairman microphone unit with display.
• The request-to-talk is registered in the system by pressing the micro-
phone button (8) of the microphone unit.
• The allocation is made by the operator at the PC or touchscreen of the
media control system.
• The LED (7) is illuminated red to indicate the request-to-talk.
• If you press the microphone button again the request-to-talk is
cleared. The LED (7) goes out.
• With the MCW-D 200 Editor Software all or individual participants can
receive messages.
• After having sent the message, it is shown on the display (11) of the
MCW-D 2071/2073 microphone units or the MCW-D 2673 with the
CA 2473-2 operating unit.
®
,