INSTALLATION
Installation
19
f Remove the transport protection plugs from the appliance
f
connections.
f Fit the appliance pipes with flat gaskets onto the twin
f
connectors.
Making the electrical connection
WARNING Electrocution
Carry out all electrical connection and installation work
in accordance with relevant regulations.
WARNING Electrocution
Connection to the power supply is only permissible in the
form of a permanent connection in conjunction with the
cable grommet. Ensure the appliance can be separated
from the power supply by an isolator that disconnects all
poles with at least 3 mm contact separation.
WARNING Electrocution
Ensure that the appliance is earthed.
Material losses
!
Observe the type plate. The specified voltage must match
the mains voltage.
f Connect the power cable to the mains terminal (see chapter
f
"Installation / Specification / Wiring diagram").

10.2 Installation options

10.2.1 Power cable for finished walls
Material losses
!
If you break open the wrong knock-out in the appliance
cover by mistake, you must use a new appliance cover.
f Cleanly cut or break out the required opening in the appli-
f
ance cover (see chapter "Installation / Specification / Dimen-
sions and connections"). If necessary, use a file.
f Route the power cable through the cable grommet. Connect
f
the power cable to the mains terminal.
www.stiebel-eltron.com
24
10.2.2 Connecting a load shedding relay
Install a load shedding relay in the distribution board in conjunc-
tion with other electric appliances, e.g. electric storage heaters.
The relay responds when the instantaneous water heater starts.
Material losses
!
Connect the phase that switches the load shedding relay
to the indicated terminal of the mains terminal in the ap-
pliance (see chapter "Installation / Specification / Wiring
diagram").
10.2.3 Water installation on finished walls
f To seal the connection on unfinished walls, fit the water
f
plugs with gaskets.
f Fit a suitable pressure tap.
f
1
1 Openings
2 Cover guides
3 Lower fixing screw
Material losses
!
If you cut open the wrong knock-out in the appliance
cover by mistake, you must use a new appliance cover.
f Secure the back panel with an additional screw at the
f
bottom.
f Secure the connection pipes to the appliance.
f
f Cleanly break out the knock-outs in the appliance cover. If
f
necessary, use a file.
f Click the cover guides into place in the openings.
f
3
2
DHF-C |
25

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Dhf 15 cDhf 18 cDhf 21 cDhf 24 cDhf 12 c1Dhf 13 c3

Table des Matières