The following table provides information regarding the recommended length versus wire cross-section. Two cases are
possible depending on the impedance load connected to the LA4 (8 Ω for a single 12XT enclosure, 4 Ω for two 12XT
enclosures in parallel):
Table 1: Maximum wire length versus cross-section for Damping Factor > 20
Cross-section
2
mm
SWG
2.5
15
4
13
6
11
10
9
According to the calculation in Table 1 one SP25 cable (4mm², 25m) can be used to power two 12XT in parallel (4 Ω
load) with a damping factor still greater than 20.
12XT_UM_ML_1.2
All manuals and user guides at all-guides.com
Length for one 12XT / 8 Ω
AWG
m
13
30
11
50
9
74
7
120
w w w . l - a c o u s t i c s . c o m
Length for two 12XT / 4 Ω
ft
m
100
15
160
25
240
37
390
60