Problem
A rectangular symbol
is shown on the right
side of the Tempera-
ture Display
8.1 Closing the door
1.
Clean the door gaskets.
2.
If necessary, adjust the door. Refer to

"Installation".

9. INSTALLATION
WARNING!
Read the "Safety Information" care-
fully for your safety and correct op-
eration of the appliance before in-
stalling the appliance.
9.1 Positioning
This appliance can be installed in a dry,
well ventilated indoor (garage or cellar) also,
but for optimum performance install this
appliance at a location where the ambient
temperature corresponds to the climate
9.2 Levelling
All manuals and user guides at all-guides.com
Possible cause
Temperature sensor prob-
lem
Solution
Call the service personnel
3.
If necessary, replace the defective door
gaskets. Contact the Service Center.
class indicated on the rating plate of the
appliance:
Cli-
Ambient temperature
mate
class
SN
+10°C to + 32°C
N
+16°C to + 32°C
ST
+16°C to + 38°C
T
+16°C to + 43°C
When placing the appliance ensure that it
stands level. This can be achieved by two
adjustable feet at the bottom in front.