Schaudt LAS 1218-2 Notice D'utilisation Et De Montage page 35

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Pos.
DC/AC
DT.../LT...
EBL ...
Fa
Fb
F1
F2
F3
810.523 BA / EN
Heruntergeladen von
manualslib.de
Instruction Manual and Installation Instructions LAS 1218-2
F4 (flat push-on contact 6.3 x 0.8) to + battery terminal (ring terminal, M6
or M8)
LAS 1218-2 to additional battery connection
-- terminal of LAS 1218-2 (flat push-on contact 6.3 x 0.8)
F
-- terminal of battery (ring terminal, M6 or M8)
F
Label the additional fuse with sticker "F4 -- additional battery".
12 V
--
--
Fig. 7
Name
Inverter
DT ... or LT ... control and display pa-
nel in the vehicle
Electroblock
Fuse, EBL ... charge current for starter
battery
Fuse, EBL ... charge current for living
area battery
Fuse, starter battery -- cut-off relay
Fuse, cut-off relay -- additional battery
Fuse, inverter supply
Handbücher-Suchmachiene
230 V
D+
B
G
Fa
Shunt
+
Fb
G2
F1
--
+
G1
F2
F3
+
G3
F4
Example circuit diagram, inverter installation
(grey background: LAS 1218-2 battery charger with connector set)
Pos.
F4
G
G1
G2
G3
K1
LAS 1218-2 Battery charger
LAS
Date: 06.11.2014
LRS
DT ... /
LT ...
EBL ...
K1
12 V
230 V
230 V
DC/AC
Name
Fuse, additional battery charge current
Vehicle alternator (higher rating)
Starter battery
Living area battery
Additional battery
Cut-off relay, starter battery -- additio-
nal battery
Charger module of electroblock
LAS 1218-2
+
--
15

Publicité

Table des Matières
loading