Instruction Manual and Installation Instructions LAS 1218-2
The connector cable (Pos. 2 or 3) is required to connect the LAS 1218-2
battery charger to the electroblock.
Fusing
An additional fuse is not required as there is already one integrated in the
electroblock. You only have to check if the fuse is fitted and if it complies
with the fuse rating on the label.
The battery charger is connected to the electroblock with a 2-pin charger ca-
ble. Other lengths are available on request.
A connection to the starter battery is not required, because the electroblock
already has the start battery recharge module.
1
Fig. 3
Connection Diagram of LAS 1218-2 Battery Charger - - on Electroblock
1
Flat push-on contacts, 6.3 x 0.8, red cable
2
Flat push-on contacts, 6.3 x 0.8, brown cable
3
not assigned
4
+ Living area battery (red)
5
Negative battery (brown)
2-pin charger cable: LAS 1218-2 to electroblock connection
+ terminal of LAS 1218-2 living area battery: Flat push-on contact, 6.3
F
x 0.8; (Fig.3; Pos. 1)
-- terminal of LAS 1218-2: Flat push-on contact, 6.3 x 0.8; (Fig.3;
F
Pos. 2)
MNL connector (view X, Fig. 3; Pos. 4/5) or Minifit connector on elec-
F
troblock, base "auxiliary charger" ; see also instruction manual for
electroblock
Handbücher-Suchmachiene
3
2
X
Date: 06.11.2014
X
4 5