Quick start guide - Network Video Recorder - TR0802P & TR1602P
Alarm Connection
2.3.3
To connect alarm devices to the NVR:
Step 1 Disconnect pluggable block from the ALARM IN /ALARM OUT terminal block.
Step 2 Unfasten stop screws from the pluggable block, insert signal cables into slots and fasten stop screws. Ensure
signal cables are tight.
Step 3 Connect pluggable block back into terminal block.
Controller Connection
2.3.4
To connect a controller to the NVR:
Step 1 Disconnect pluggable block from the KB terminal block.
Step 2 Unfasten stop screws from the KB D+, D‐ pluggable block, insert signal cables into slots and fasten stop screws.
Ensure signal cables are in tight.
Step 3 Connect Ta on controller to D+ on terminal block and Tb on controller to D‐ on terminal block. Fasten stop
screws.
Step 4 Connect pluggable block back into terminal block.
Make sure both the controller and NVR are grounded.
Network Video Recorder Quick Start Guide
Figure 2‐7 Controller Connection
11
11
EN