Baxtran BR 15 Mode D'emploi page 49

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CALIBRATION OF THE WEIGHT
DISPLAY
LF 1
maximum capacity and it must also never be exceeded.
CAL Z
•Press the key
the menu LF1)
150.00 kg
•Use
calibration will be done. ( press the key
•Place the required weight on the scale as it is indicated in the display.
150.00 kg
150.00 kg
•Once everything is steady, press the key
and go back to the menu LF1).
THE CALIBRATION IS GOING TO FINISH AND THE SCALE WILL GO VACK TO THE WEIGHING MODE AUTOMATICALLY.
CONFIGURATION
LF 2
DISPLAY
FIRST STEP
262144
•DISPLAY OF THE INTERNAL COUNTING
•POSSIBLE VALUES OF THE PARAMETERS
SECOND STEP
A: Metric system
B: American system
1 0 0 0 0 1
C: other unities
D: PCS
A B C D E F
E: double range
F: units of calibration
THIRD STEP
•Use
considering the number of decimal zeros to be used. Ex. 150.00kg = introduce 15000 if then selected
000000kg
as decimal d0.00
FOURTH STEP
•Use the Keys
dP 0.0
FIFTH STEP
•Use
diV 01
diV 01, diV 02, diV 05, diV10, diV 20, diV 50
steps to follow must be completed, if they are not done the indicator will continue with the previous
configuration.
LF 1
DESCRIPTION AND SEQUENCE OF USE
The calibration can be done with any weight, but the weight can not be lower than 1/3 of the
to start the calibration of zero ( press
0 ~ 9
,
and
,
DESCRIPTION AND SEQUENCE OF USE
0:NO
0:NO
0:NO
0:OFF
0:OFF
lb oz cannot be selected as unities of calibration.
The scale won't let us continue up to the next step if there is a mistake during the programming.
0 ~ 9
,
and
,
,
to change the position of the DECIMAL POINT.
d 0.00
d 0.000
to select the DIVISION:
After introducing the parameters LF2, the indicator will show the last configuration saved. All the
Proceed with the calibration of weight after LF2.
To exit the calibration and go back to
and then press
to introduce the weight with which the
to exit the calibration and go back to the menu LF1)
to calibrate it ( press the key ESC to exit the calibration
1: kg
2:T
1: lb
2:lb oz
1: TW kg
2:HK kg
1: ON
1: multi interval
2:multi range
1:use metric
2:use american unities
unities
and then press
to introduce THE MAXIMUM CAPACITY,
d 0.0000
USER'S MANUAL BR15
3:g
3:VISS
0.00000
EN
49

Publicité

Table des Matières
loading

Table des Matières