Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 15
6
www.aeg.com
• Do not cause damage to the part of
the cooling unit that is near the heat
exchanger.

3. INSTALLATION

WARNING!
Refer to Safety chapters.
3.1 Positioning
This appliance can be installed in a dry,
well ventilated indoor where the ambient
temperature corresponds to the climate
class indicated on the rating plate of the
appliance:
Climate
class
SN
N
ST
T
3.2 Location
It must be possible to
disconnect the appliance
from the mains power
supply. The plug must
therefore be easily
accessible after installation.
The appliance should be installed well
away from sources of heat such as
radiators, boilers, direct sunlight etc.
Ensure that air can circulate freely around
the back of the cabinet. To ensure best
performance, if the appliance is
positioned below an overhanging wall
unit, the minimum distance between the
top of the cabinet and the wall unit must
be at least 100mm. Ideally, however, the
appliance should not be positioned
below overhanging wall units. One or
more adjustable feet at the base of the
cabinet ensure that the appliance stands
level.
Ambient temperature
+10°C to + 32°C
+16°C to + 32°C
+16°C to + 38°C
+16°C to + 43°C
A
CAUTION!
In order to guarantee proper
functioning in ambient
temperature above 38°C, it
is advised to have a 30mm
separation between the
sides of the appliance and
surrounding furniture.
3.3 Levelling
Accurate levelling prevents the vibration
and noise of the appliance during
operation.
To adjust the heigh of the appliance
loosen or tighten the two adjustable
front feet.
B

Publicité

Table des Matières
loading

Table des Matières