The "O P PFF" display is lit.
The output current is limited to
5 A, although the current settings
are higher.
The "C.C." LED is lit.
The "C.V." LED is lit.
OVP
OtP
OLP
Repairs other than those described above may only be carried out by an authorised
specialist. If you have any questions concerning the handling of the device, please
do no hesitate to contact our Technical Support:
Voltcraft®, 92242 Hirschau, Lindenweg 15, phone 0180 / 586 582 7
16.

dISPoSAL

Electronic devices are recyclable waste and must not be disposed of in the household
waste!
At the end of its service life, dispose of the product according to the relevant statutory
regulations.
56
The DC output was switched off through the remote control
output (10). Release the connection between contacts 4 and 5.
The output is switched on again.
The output current is limited to 5 A. For higher currents,
connect the consumer to the rear main output.
Constant current operation:
The preset current was exceeded. Check power consumption
on your consumer and increase the current limitation on your
power unit, if applicable.
Constant voltage operation:
The power unit works normally. The output provides the
constant voltage set.
Over-voltage protection:
See chapter PROTECTIVE MEASURES.
Overheating protection:
See chapter PROTECTIVE MEASURES.
Overload-protection:
See chapter PROTECTIVE MEASURES.