REGULAR SAFETY INSPECTION

Description of the product

Serial number
Verification phase
Presence of the technical panel on the hydraulic unit with
the serial number of the lift
Presence of the maximum load of 2000kg/4400lbs on the
lift with the serial number.
Up and down signalling by an arrow on the remote control
Presence of the operating instructions (original)
Tightening of nuts on all axes
Condition of hydraulic hoses and couplings
Status of the wired remote control and its power cord
The buttons on the wired remote control return to the 
initial position automatically and charging stops.
The emergency stop button is functional.
Condition of the load‐bearing construction (mechanical 
structure)
Functioning of the locking notches of the 4 supporting
elements and presence of the angular stops and locking
of the runners in their supports.
Condition of the cylinders (leaks, rust...)
Condition of the rubber pads 
Condition of the power cord of the hydraulic power pack
General condition of the hydraulic unit
Double  beep  when  the  lift  reaches  its  maximum 
position. 
Each  time  the  descent  button  is  pressed,  a  beep  will 
sound for 2 seconds before the table is lowered and an 
audible signal will be emitted throughout the descent.  
Functional  test  of  the  lifting  platform  with  vehicle 
(ideally with a weight close to 2T / 
Control result
Security check carried out on: ................................................................................................
Name and address of the authorised person: ....................................................................................
4400lbs
)
Commissioning is not allowed
No anomalies: commissioning granted
ERGO LIFT 650
NOT
OK
OK
Signature of the authorised person
ERGO LIFT 650
Remarks
45 