Maintenance Table; Maintenance Intervals - GYS Ergo Lift 650 Manuel D'utilisation Et De Maintenance

Élévateur
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

 

MAINTENANCE TABLE

Maintenance
intervals
Monthly
Annual
Replace the hydraulic hose in case of heavy use
and change the oil.
Every 5 years
of service
 
Use the "Regular Security Check" and the "Maintenance Log" forms to archive regular and annual checks.
Carry out a report on the condition of the ERGO LIFT every year and enclose it with the operating instructions.
Regular safety checks must be carried out by an authorised person. It is recommended to perform
maintenance at the same time and refer to this manual for troubleshooting.
Task
Check, clean and lubricate all moving parts,
especially the joints.
Check that the locking system of the 4 load-
bearing elements is working properly and that
the stops are present.
Check the condition of the rubber pads and
clean them if necessary.
Check the condition of the hydraulic hoses,
the cable of the wired remote control and the
power supply cable.
Check the hydraulic oil level
Check the structure visually.
Carry out an unladen ascent over the full
stroke of the lift.
Check that the limit switch is working correctly
(double beep when the lift is in the maximum
position).
"Regular security check"
ERGO LIFT 650
Remarks
Refer to "Check and Lubrication
Point (page 35)".
Replace if necessary
(Refer to the exploded view)
If necessary, top up the level: Use
an oil with a viscosity of 32CST (ref
062160 / canister 5L) page 36.
See page 30 for a description of
the procedure which describes
normal behaviour and page 36
which describes the operation of
the limit sensor.
To be carried out by an authorised
person and to be completed and
signed.
Replace if you notice a decrease in
climb speed. A hose crushed by
the passage of car wheels over the
course of use may be the cause
(Ref. 70887 - hydraulic hose).