MAINTENANCE
9. Soak all of the removed parts and the scoop in the sanitizing solution for 10 minutes. If the spray
assembly nozzles are clogged, clean them with a wire or a suitable brush.
10. Rinse the parts thoroughly with clean water.
11. Refit the 2 caps in their correct positions. Make sure the reducing pipe is in place in the center.
See Fig. 42.
12. Slide in the spray assembly along the rails on the left and right brackets. See Fig. 43. Connect the
discharge tube securely to the spray assembly; a loose fitting may cause a water leak.
Reducing Pipe
Fig. 42
13. Position and lock the ice chute onto the front and rear frame pipes by pushing the ice chute
down until it clicks onto both frame pipes. See Fig. 44.
14. Slide in the water tank along the rails at the bottom of the left and right brackets until it locks
into place. See Fig. 45.
Rear Frame
Pipe
Front Frame
Pipe
Fig. 44
15. Reconnect the suction tube.
16. Hook each separator onto the rail, then pull it hard towards you until it locks into place. See Fig.
46.
17. Replace the slope in its correct position. See Fig. 47.
Separator
Fig. 46
(continued)
Left Bracket
Caps
Ice Chute
Rail
Rail
Discharge Tube
Fig. 43
Left Bracket
Rail
Slope
Fig. 47
©2021 Hestan Commercial Corporation
Right Bracket
Rail
Right Bracket
Rail
Water Tank