Télécharger Imprimer la page

Key Automation CT102 24 Instructions Et Avertissements Pour L'installation Et L'usage page 19

Logique de commande pour un moteur 24 vdc, pour portail coulissant, porte basculante ou barrieres

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 30
- Power supply with protection against short-circuits inside the con-
trol unit, on motors and on the connected accessories.
- Obstacle detection.
- Automatic learning of working times.
TECHNICAL SPECIFICATIONS:
Power supply (L-N)
Max motor load
Output for Vac accessories power/device test power Vdc
Courtesy light output
Flashing light output
Pause time
Operating temperature
230 Vac power supply line fuses
Max. number of transmitters storage FIX CODE
Max. number of transmitters storage ROLLING CODE
2.4 - List of cables required
The cables required for connection of the various devices in a stan-
dard system are listed in the cables list table.
ELECTRIC CABLE TECHNICAL SPECIFICATIONS:
Connection
Control unit power supply line
Flashing light, courtesy light
Antenna
Electric lock
Transmitter photocells
Receiver photocells
Sensitive edge
Key-switch
* If the power supply cable is more than 20 m long, it must be of larger gauge (3x2.5mm2) and a safety grounding system must be installed
near the automation unit.
3 - PRELIMINARY CHECKS
Before installing the product, perform the following checks and in-
spections:
check that the gate, the door or the barrier is suitable for automation;
the weight and size of the gate or door and the balance of the barrier
boom must be within the operating limits specified for the automa-
tion system in which the product is installed;
heck that the gate or door has firm, effective mechanical safety
stops;
make sure that the product fixing zone is not subject to flooding;
high acidity or salinity or nearby heat sources might cause the pro-
duct to malfunction;
in case of extreme weather conditions (e.g. snow, ice, wide tempe-
rature variations or high temperatures), friction may increase, cau-
sing a corresponding rise in the force needed to operate the system;
- Safety device deactivation by means of dip switches: there is no
need to bridge the terminals of safety devices which are not instal-
led - the function is simply disabled by means of a dip switch.
230 Vac (+10% - 15%) 50-60 Hz
150 W
24 Vac without regulation 200 mA / 24 Vdc without regu-
lation 250 mA
24 Vdc 25 W
24 Vdc 25 W
Adjustable 0-900 sec.
-20 °C + 55 °C
1.6 A slow-acting
150 transmitters
150 transmitters
The cables used must be suitable for the type of installation; for
example, an H03VV-F type cable is recommended for indoor appli-
cations, while H07RN-F is suitable for outdoor applications.
cable
1 x cable 3 x 1,5 mm
2
3 x 0,5 mm
**
2
1 x cable type RG58
1 x cable 2 x 1 mm
2
1 x cable 2 x 0,5 mm
2
1 x cable 4 x 0,5 mm
2
1 x cable 2 x 0,5 mm
2
1 x cable 4 x 0,5 mm
**
2
the starting torque may therefore exceed that required in normal
conditions;
check that when operated by hand the gate, the door or the barrier
moves smoothly without any areas of greater friction or derailment
risk;
check that the gate, door or the barrier is well balanced and will the-
refore remain stationery when released in any position;
check that the electricity supply line to which the product is to be
connected is suitably earthed and protected by an overload and dif-
ferential safety breaker device;
he system power supply line must include a circuit breaker device
with a contact gap allowing complete disconnection in the condi-
tions specified by class III overvoltage;
ensure that all the material used for installation complies with the
relevant regulatory standards.
maximum allowable limit
20 m *
20 m
20 m (advised < 5 m)
10 m
20 m
20 m
20 m
20 m
EN
19

Publicité

loading