While the Coniston has been designed for use with 700 mm, 750 mm and
800 mm wide baths, the width of an installed bath may vary in that the
longside of the bath rim next to the wall may be fully buried.
If you have an insufficient amount of the bath rim exposed, it is strongly
advised that you install our wall fixed support plate, this is designed to
prevent the Coniston tilting whilst in use.
Contact the Aidapt Equipment Sales Office on +44 (0) 1744 745 045 for
more details.
6.
The side arms of the Coniston rotating bather can also be adjusted. To adjust the
arms, turn the seat part of the bather upside down.
Adjusting one arm at a time press down on the two gold domed clips holding the
arms in place, slide the arm to the desired width ensuring the domed clips pass
back through the frame (see fig. 3).
Repeat the process for the other arm ensuring that both arms are adjusted to the
same width.
7.
Once you have adjusted the width adjusters (and side arms if necessary) to suit the
bath carefully place the base section onto the bath rim (long edge).
Undo the nuts holding the side supports in place by hand. Adjust both supports
equally until both grippers are equally adjusted and gripping the side of the bath.
When the side supports are properly adjusted tighten the nuts to keep the base of
the unit in place.
8.
Once you are satisfied that the base unit is correctly installed you are now ready to
attach the seat.
Carefully lift the seat section onto the top of the base ensuring that the female
locator hole on the base of the seat (see fig. 4) is lined up and located onto the
spline of the base section and lower into place.
Fixing and Maintenance Instructions
fig.3
fig. 4
4
Ver.4 08/2012 (1562)