screen, by pressing the  cursor key (see Display 7), either for viewing or
for entering or changing/confirming them.
The "Resistance" option of this menu allows measuring the actual resis-
tance of the connected electrofusion fitting before the welding process
proper starts. When this option is called (selection using the ñ, ò arrow
keys, confirmation by pressing START/SET), the appropriate access code
has to be entered and confirmed by START/SET first before resistance
measuring actually starts.
The access code for measuring the actual resistance is disclosed
to a responsible person with the owner/operator of the welding
system and has to be requested from this person.
Info
6.2

Entering or Changing the Job Number

The commission number input screen is shown by the unit before welding
or accessed by the user in the quick access screen (Display 7). It can be
entered using the alphanumeric keypad (see Info in Sect. 5.2) or by reading
it from a bar code using the scanner. The maximum length is 32 characters.
Confirm your input by pressing the START/SET key. The job number will be
saved to memory and will appear in the printed welding report.
6.3

Entering or Changing Additional Data

The additional data input screen is shown by the unit before welding, first
the screen that allows entering the first additional data, then the one for
the second additional data. This input can be entered either using the
alphanumeric keypad (see Info in Sect. 5.2) or by reading from a bar code
using the scanner.
For the first additional data input, the maximum length is 20 characters.
For the second data input, the maximum length is 15 characters. Confirm
your input by pressing START/SET. The additional data will be saved to
memory and appear in the welding report. By pressing STOP/RESET, you
skip this screen without any input.
You are free to define any additional data you see fit. For instance,
you can put into these fields information on pipe length, ditch
depth, or comments that help with welded joint traceability.
Info
6.4

Entering the Fitting Traceability Code

If this feature is enabled in the configuration menu, after the fitting code
was entered, another input "Fitting Code" is required. This is the so-called
"traceability code" or "second fitting code" of the fitting.
This input is entered either from a bar code using the scanner or manually
using the alphanumeric keypad (see Info in Sect. 5.2). Press the START/
SET key to confirm your input. If the code entered is not correct, a "Code
Error" message appears; check the string of numbers and correct as needed.
If the code entered is correct, it is saved to system memory and inserted
into the welding reports to be printed. By pressing the STOP/RESET key,
you skip this input.
6.5

Entering the Pipe Codes and the Installing Company

In the same manner as the fitting traceability code (see Sect. 6.4), enter-
ing the ISO-compliant codes of both pipes or reading them from a bar
code is possible, if this feature was enabled in the configuration (see
Sect. 10.2).
The same holds for the company installing the pipes, which can be entered,
max. 15 characters, if the option was enabled in the configuration menu.
T E G A M u h e n d i s l i k S a n a y i v e T i c a r e t A . Ş .
06930 Sincan Ankara, Turkey
All manuals and user guides at all-guides.com
English
Enter Job No.
********************
************
Enter Add. Data 1
********************
*** Fitting Code ***
********************
******
4000-S
11
Display 8
Display 9
Display 10

Publicité

Table des Matières
loading

Table des Matières