Télécharger Imprimer la page

AirKing EVD Serie Instructions Importantes – Mode D'emploi page 4

Ventilateur combiner, comprend lumière et ventilation

Publicité

Les langues disponibles

Les langues disponibles

Standard Models
Figure 11
3b.
MOTION SENSING MODELS: Plug the
fan's 2 pin and 3 pin quick connect motor
cords into the receptacles located on the
side of the wire compartment. Plug the 3
pin quick connect cord from the motion
sensor on the grill into the receptacle
coming out of the top of the wire
compartment. These cords will only fit one
way into the receptacles (Figure 12).
4.
VARIABLE SPEED: First decide if you
will require more or less than 65 CFM
of ventilation on the low speed setting.
If it is less than 65 CFM place the Low
CFM Range rocker switch on the 30-60
range. If it is more, place the low CFM
range rocker switch on the 70-120 range.
Once you have decided on the minimum required airflow, the fans low speed CFM level
can be adjusted by using either the lower adjustment knob (30-60 CFM) or the middle
adjustment knob (70-120 CFM). The desired high speed CFM can be adjusted by using
the upper most adjustment knob (Figure 13).
Rocker Switch
Adjustment
Knobs
Figure 13
5.
Install the ceiling mounting flange to cover any gaps which exist between the housing and
the finished ceiling. Remove the two screws that connect the ceiling mounting flange to the
housing. Put sealant (not provided) on inside edge of the ceiling mounting flange to ensure
that the flange is sealed to the ceiling. Line up the screw holes in the ceiling mounting flange
with the screw holes on the inside of the housing and press flange in place so it is tight
against the ceiling. Reinstall ceiling flange mounting screws inside the housing (Figure 14).
Ceiling
Mounting
Flange
Figure 14
NOTE: If the housing is mounted too far or not far enough into the ceiling for the flange to
make a solid connection, loosen the mounting channel and adjust the housing up or down on
the rails. Once in place, fully tighten the mounting channel nuts.
6728050 Rev. J 9-16
Humidity Sensing Models
Motion Sensing Models
Figure 12
Screws
Screw Holes
www.airkinglimited.com
STANDARD AND HUMIDITY SENSING MODELS: Install the grill by squeezing the two
6a.
ends of the springs together and installing them up into the slots on the fan's housing.
Push the grill up into position (Figure 15).
Figure 15
6b.
MOTION SENSING MODELS: Install the grill by squeezing the spring furthest from
the motion sensor together and installing it up into the slot furthest from the wire
compartment on the fan's housing. Attach the 3 pin quick connect from the motion sensor
on the grill to the harness installed in Step 2a. This cord will only fit one way into the
receptacle. Install the other spring in place and push the grill up into position (Figure 16).
Figure 16
7.
Restore power and test your installation.
SECTION 7
Programming the Occupancy Sensor
1a. Setting the Occupancy Time Delay. This will set the amount
of time the fan will continue to operate on high speed after the
room is vacated. Locate the motion sensor on the fan's grill and
press the button 2 times. The LED on the sensor will then flash
the number of times to indicate the current setting, this will
repeat 3 times:
1 time = 30 seconds
2 times = 2.5 minutes 6 times = 12.5 minutes
3 times = 5 minutes
7 times = 15 minutes
4 times = 7.5 minutes 8 times = 17.5 minutes
5 times = 10 minutes 9 times = 20 minutes
1b. To adjust the setting, while the sensor is still flashing from Step 1a, press the button the
number of times that corresponds with the amount of time you desire, for instance 3 times
sets the delay to 5 minutes (see numbers in Step 1). The sensor will then flash the number
of times for the new setting 3 times before exiting back to the programming mode.
2a Setting the Minimum On Time. This sets the minimum time the fan will operate on
high speed once motion is detected within the room. This works in conjunction with
the Occupancy Time Delay feature set in Steps 1a and 1b. For instance if you set the
minimum time on for 15 minutes and the Time Delay for 5 minutes, the fan will operate
for at least 15 minutes then 5 additional minutes.
NOTE: This is a minimum time that the fan will operate. If the room is occupied longer, the
fan will continue to run until the room is vacated and the occupancy time delay has elapsed.
2b. Locate the motion sensor on the fan's grill and press the button 10 times. The LED on the
sensor will then flash the number of times to indicate the current setting, this will repeat
3 times:
1 time = 0 minutes
4 times = 45 minutes
2 times = 15 minutes 5 times = 60 minutes
3 times = 30 minutes
2c. To adjust the setting, while the sensor is still flashing from Step 2b, press the button
the number of times that corresponds with the amount of time you desire, for instance
3 times sets the minimum on time to 30 minutes (see numbers in Step 2b). The sensor
will then flash the number of times for the new setting 3 times before exiting back to the
programming mode.
3.
Once all setting have been made and the sensor will return to detection mode and the
LED will flash when occupancy of the room is detected.