ENGLISH

8. Storing the generating set

Generating sets which remain unused for a long period of time must undergo certain procedures in order to keep
them in good condition. Check that the storage area is not dusty oy humid. Clean the exterior of the generating set and
apply a rustproofing product.
• Close the fuel trap.
• Change the motor oil.
• Remove the spark plug and pour about 15 ml of oil into the cylinder, then refit the spark plug.
• Holding the starter handle correctly, pull it out slowly as far as it will go several times to run the motor and distribute
the oil around the cylinder.
• Clean the generating set, cover it to protect it from dust and store it in a clean and dry place.

9. Fault finding

The generating set is being charged during start-up
Fuel level is too low
The fuel tap is closed
The motor will not start
Fuel supply blocked or leaking
Clogged air filter
Switch on "O"
Faulty spark plug
Blocked ventilation inlets
The motor cuts out
Possible overload
Circuit breaker tripped out
Faulty circuit breaker
No electric current
Faulty plug socket
Faulty appliance supply lead
Faulty alternator
Circuit breaker trips out
Faulty equipment or lead

10. Specifications

MODEL
Motor type
max 50 Hz (Watt) output
Alternating current
Direct current
Type of alternating current socket
Type of direct current socket
Circuit breakers
Oil failure cut - out
E.C.C. sound
Weight in Kg (without fuel)
Dimensions l x w x h in cm
Recommended oil
Oil sump capacity in L
Recommended fuel
Fuel tank capacity in L
Spark plug
: standard
: optional
PROBABLE CAUSES
X: impossible
REMEDIAL ACTIONS
Take it off charge
Fill up with fuel
Open the fuel tap
Have the system repaired
Clean the air filter
Move the switch to "I"
Replace the spark plug
Clean the air inlet and outlet guards
Check the load
Reset the circuit breaker
Have it checked, repaired or replaced
Have it checked, repaired or replaced
Change the lead
Have it checked, repaired or replaced
Have it checked, repaired or replaced
AY-1000 KT
4 - stroke, air cooled
800
230 V - 3,9 A
12 V - 5 A
1 x 16 A
1 x 5 A
93
28
48 x 33 x 42
SAE 15 W 40
0,37
Unleaded petrol
5
BPR 6 ES
17