1.3.10 Danger of moving parts
Never go near a moving part that is in operation if you have loose clothing or long hair that is not
enclosed in a protective hair net. Do not try to stop, slow down or impede a mpving part when it
is in operation.
Warning
1.3.11 Capacity of the generating set (overload)
Never exceed the rated load of the generating set (in Amps and/or Watts) when it is running continuosusly.
Before connecting and operating the generating set, calculate the electrical power required by the electric
appliances (in Watts). This electrical power rating is ususlly found on the manufacturer´s plate on bubs, electrical appliances,
motors etc. The sum total of power required by these appliances should not exceed the nominal power rating of the
generating set.
1.3.12 Operating condicions
The stated outputs of the generating sets are obtained in example conditions according to ISO 3046-1:
+ 27ºC, 100 m above sea-level, humidity level equal to 60%, or
+ 20ºC, 300 m above sea-level, humidity level equal to 60%.
Performance is reduced by approximately 4% for every additional 10ºC and/or approximately 1& for every
additional 100 m in altitude.

2. General description

2.1 Description of the generating set
Fuel tank cap
Fuel tank cap air vent tab
Starter handle
Fuel tab
Starter
Accesoriess: battery supply lead, Spark plug spanner, Screwdriver bit, Screwdriver handle, Removal spanner.

3. Preparation before starting

3.1 Checking the oil level
Always check the engine oil level before starting.
Checking and topping up should be carried out with the generating set on horizontal surface.
• Remove the protective cover by unscrewing retaining bolt.
• Remove the cap/gauge by unscrewing it to check the level. Top it up if necessary.
• Fill the oil sump to the top using a funnel.
• Screw the cap back fully and check there are no leaks.
• Wipe off excess oil with a clean cloth.
• Secure the protective cap by tightening the retaining bolt.
Earth socket
DC circuit breaker on/off button
AC circuit breaker reset button
AC electric socket
DC electric socket
On/off switch
Oil fill/drain access cover removal screw
Oil fill/drain access cover
Spark plug access cover