CV67
to
CV94
Speed steps table, user-programmable (see CV 29): The
speed table is always saved with 28 speed steps to be pro-
grammed in CV67 to CV94.
With LGB MTS, every second value is skipped (14 speed
steps). Factory-set speed steps:
7, 9, 11, 13, 16, 20, 24, 28, 32, 36, 42, 48, 54, 60, 68, 76, 84,
92, 102, 112, 124, 136, 152, 168, 188, 208, 230, 255
Pre-set values for user-programmable speed steps:
8, 16, 24, 32, 40, 48, 56, 64, 72, 80, 88, 96, 104, 112, 120,
128, 136, 144, 152, 160, 168, 176, 184, 192, 208, 224, 240,
255
Note:
The speed steps are factory-set and needn't be changed.
We recommend the 55045 MTS PC Decoder Programming
Module for programming.
Example for bit programming:
CV 29: A loco shall run in reverse direction with user-
programmed speed steps, analog operation shall be possible:
Bit 1 = 1, Bit 2 = 0, Bit 3 = 4, Bit 4 = 0, Bit 5 = 16,
Bit 6 = 0. 1+4+16=21.
Thus, program CV 29 to function value 21.