Télécharger Imprimer la page

Ferroli EGEA 200 LT Manuel D'utilisation, Installation Et Entretien page 105

Publicité

Les langues disponibles
  • FR

Les langues disponibles

EGEA
200 LT - 260 LT - 200 LT-S - 260 LT-S
OUTPUTS
230 Vac - 16 A relay output with N.O. contact. for solar thermal /
DHW recirculation circulating pump (ON/OFF type).
230 Vac - 5 A relay output with contact N.O. for solar collector
shutter / drain valve.
Only for models LT-S
Note: For more information on remote connections and the
configuration of the equipment with these systems, see the
par. "7.5 OPERATING MODE" and "8.1.1 List of equipment
parameters".
6.8.1.1 Remote connection
For the connection to the digital inputs the equipment is sup-
plied with an additional 6-core cable already connected to the
PCBA of the user interface (located inside the device). The re-
mote connections to possible energy systems are the responsi-
bility of the qualified installer (connection boxes, terminals and
connection cables).
The following figures give an example of remote connection (fig.
24 and fig. 25) which must not be longer than 3 m.
fig. 24- Example of remote connection
To access the 6-core cable for remote connection, remove the
upper cover of the boiler and run to the outside the cable, al-
ready present inside the unit, through the special cable gland
installed in the back cover.
cod. 3541T600 - Rev. 08 - 12/2021
1
2
3
4
5
6
fig. 25
EN
105

Publicité

loading

Ce manuel est également adapté pour:

Egea 260 ltEgea 200 lt-sEgea 260 lt-s