See Quick Guide: Selection of settings for daylight factor page 8:
For details, see:
www.servodan.dk
Protected mode (Backup mode).
For additional protection against "busy fi ngers" adjusting the
unit, it is recommended that a copy of the customer settings be
made to back up the settings and then select "Run" in backup
mode.
For details, see:
www.servodan.dk
Glossary
Application (App. 10.01, 11.01, 12.01, 13.01 and 14.01):
Pre-programmed functionality in the Luxstat.
Range:
Working range for light measurement.
Lx ind1, Lx ind2, Lx ind3:
Current light level (lux) at selected reference point (table height)
in zones 1-2-3, measured with a luxmeter.
Adjust Ch1, Adjust Ch2, Adjust Ch3:
Controls lighting in zone 1, zone 2 and zone 3 of the premises.
Setp1, Setp2, Setp3 (Setpoint):
Desired light level (lux) at table height in zone 1, zone 2, zone 3.
Vout min1, Vout min2, Vout min3:
Option for defi ning a minimum 1-10 V control signal, e.g. 2 V.
Vout max1, Vout max2, Vout max3:
Option for limiting the 1-10 V control signal, e.g. to 8 V.
Fade up1, Fade up2, Fade up3:
The ramp time for the light level of the light fi ttings from 0% to
100% is selected here.
Fade down1, Fade down2, Fade down3:
The ramp time for the light level of the light fi ttings from 100%
to 0% is selected here.
Off delay:
Time delay before the motion sensor dims the light, after the last
registered movement.
Cut off1, Cut off2, Cut off3:
Cuts off 230 V power supply to HF ballast.
Energy max.: (Loadshed1, Loadshed2, Loadshed3):
A function to reduce Vout max1, Vout max2 and Vout max3
(between 0% and 100%).
Daylight factor:
This describes the amount of daylight falling into a room.
Eco switch (To switch off):
A function whereby it is possible to manually switch off the
lighting, thus saving the cut-out delay.
Operation & maintenance
Contact a qualifi ed electrician in the event of a fault or
breakdown.
Servodan A/S | Tel +45 7442 4726 | Fax + 45 7442 4035 | info@servodan.dk | www.servodan.com
Troubleshooting
See Quick Guide:
For details, see: www.servodan.dk
Technical data
RJ12 – 1:
Pin 1 and 2 ..................................... 24 V DC +/-10% (SELV)
Pin1 Supply .................................... +
Pin2 Supply .................................... -
Pin3 I/O ........................................... Open connection.
Pin4 Ch1 ......................................... NPN 24 V / 25 mA.
Pin5 Ch 2 ......................................... NPN 24 V / 25 mA.
Pin6 Ch3 ......................................... NPN 24 V / 25 mA.
RJ12 – 2:
For updating software. Must not be used.
Power consumption:
Active .............................................. 6 VA
Standby .......................................... 2 VA
Ambient temperature ...................... 5°C to 50°C
Storage temperature ...................... -20°C to +60°C
Protection ....................................... IP 20
Dimensions .................................... Width 70 mm
CE pursuant to ............................... EN 60669-2-1
Connection of accessories
Supply to sensor in general:
Power supply: ................................. 24 V DC +/-10%, max 100 mA
ø B1 / A11 ...................................... +
ø B2 / A7 / A12 ............................... -
HF control gear:
CH1-cont.:
ø D1 .................................................. 1-10 V (term. II), I sink max. 50
mA
ø D2 ................................................ COM1
CH2-cont.:
ø D3 ................................................ 1-10 V (term. II), I sink max. 50
mA
ø D4 ................................................ COM2
CH3-cont.:
ø D5 ................................................ 1-10 V (term. II), I sink max. 50
mA
ø D5 ................................................ COM3
GB
Short circuit proof.
Short circuit proof.
Short circuit proof.
Height 55 mm
15(26)