Accessing the DL2 Datalogger over the Internet
with the VBus.net visualisation portal
The Datalogger DL2 can be easily connected to VBus.net.
Note
In order to enable VBus.net access, the Datalogger must have uncondition-
al access to the ports 80 and 1194 / 1195.
In order to access a DL2 Datalogger delivered with the firmware version 2.0.0 or
higher via VBus.net, proceed as follows:
Î Enter VBus.net into the address bar of the browser and click Sign up.
Î Wait for the confirmation e-mail to arrive.
Î Click Add new device.
Î Enter the alphanumeric 8-10-digit code (Access Token, see label).
If you do not have a token label, proceed as follows:
Î Activate VBus.net in the DL2, if necessary.
Î In the main menu Device Config, select the submenu Remote Access.
Î Note down the alphanumeric 8-10-digit code (Access Token) indicated on the
Remote access over Internet tab.
Î Enter VBus.net into the address bar of the browser and click Sign up.
Î Wait for the confirmation e-mail to arrive.
Î Click Add new device.
Î Enter the alphanumeric 8-10-digit code (Access Token)
22
www
7
Accessing the DL2 Datalogger with the RPT Para-
meterisation Tool via VBus.net
To use RPT, the VBus access over local network has to be enabled.
In order to activate the VBus access, proceed as follows:
Î In the main menu Device Config, select the submenu Remote Access.
Î On the VBus access over local network tab, in the dropdown menu Local
network access enabled? select Yes.
Î On the Remote access over Internet tab, in the dropdown menu Use
VBus.net for remote access? select Yes.
With a VBus.net account you can easily use RPT in order to parameterise the
controller:
Î In the VBus.net menu My Devices, click on Edit.
Î On the General settings page, tick the option Allow parameterization
using the via address and the RESOL Parameterization Tool (RPT).
Î Enter the Via tag from the VBus.net menu item General settings into the RPT
field URL/IP.
Î Enter the password into the Password field.
Î Click on Connect.
8

Firmware update with SD card

New firmware versions extend the functional range and enhance the operation.
The current software can be downloaded from www.resol.de/firmware.
In order to run a firmware update over the SD memory card slot, proceed as
follows:
Î Download the firmware from the Internet (www.resol.de/firmware) and save
it to your PC.
Î Extract the file.
Among the extracted files there is a folder called SDCARD.
Î Insert an SD card formatted with the FAT32 format into the PC.
Î Copy the contents of the SDCARD folder onto the first level of the SD card.