Electrical connection

Carry out the connection of the Datalogger  to other modules in the
order described below:
Î Connect the data cable (RESOL VBus
essary, extend the cable using the terminal block included and a common two-
wire cable.
Î Plug the mains adapter  into a socket.
Î For a direct connection to a router or a PC, connect the Datalogger to a rout-
er  or a PC  using the network cable (included with the DL2, ).
www.vbus.net
VBus
Power supply is carried out via an external mains adapter. The supply voltage of the
mains adapter must be 100 ... 240 V~ (50 ... 60 Hz).
The DL2 Datalogger comes with the mains adapter and the VBus
nected.
, ) to the RESOL controller . If nec-
®
www
cable pre-con-
®
4.3
VBus
/ data communication
®
Terminal connections of the Datalogger
The DL2 Datalogger is to be connected to the controller via the pre-connected
VBus
®
cable. The corresponding terminal allocation is described in the controller
manual.
The VBus
cable can be extended using the terminal block included and a common
®
two-wire cable.
The VBus
cable is pre-connected to the Datalogger terminals  and . Another
®
module can be connected to the terminals  and .
4.4

Connecting the network cable

The DL2 Datalogger can be connected to a computer or a router by using a net-
work cable (CAT5e, RJ45).
Î Connect the network cable included to the network adapter of the computer
or the router.