Pre-Installation

2 .6 Trim Garnish Dimensions

This section provides the cutting measurements for the
interior ceiling trim garnish.
A 6 in. (152 mm) trim garnish (CC) for a standard
installation is provided with your vent fan. Thinner roofs
or walls require a different trim garnish and a different
type of installation.
I
To request a trim garnish for a thinner roof or clamp-
fan installation, review "Model Identification" on
page 5 and then contact your local Dometic
service partner or dealer or the Dometic Customer
Support Center at 800-544-4881.
2 .6 .1 Opening Depth: 7/8 to 1-7/8 in .
(22 to 48 mm)
For a roof or wall thickness from 7/8 in. (22 mm) to
1-7/8 in. (48 mm), use a 1-7/8 in. (48 mm) trim garnish
and adjust the size according to the table below.
I
To request the correct trim garnish, contact
your local Dometic service partner or dealer
or the Dometic Customer Support Center at
800-544-4881.
Roof
Recommend
or Wall
Trim Garnish
Trim Garnish
Thickness
Size
7/8 in.
7/8 in.
1/2 in.
(22 mm)
(22 mm)
(13 mm)
1 in.
1 in.
3/4 in.
(25 mm)
(25 mm)
(19 mm)
1-1/4 in.
1-1/4 in.
1 in.
(32 mm)
(32 mm)
(25 mm)
1-1/2 in.
1-1/2 in.
1-1/4 in.
(38 mm)
(38 mm)
(32 mm)
1-3/4 in.
1-3/4 in.
1-1/2 in.
(45 mm)
(45 mm)
(38 mm)
1-7/8 in.
1-7/8 in.
1-5/8 in.
(48 mm)
(48 mm)
(41 mm)
*These recommended screw sizes are for a clamp-fan
installation only.
6
Minimum
Recommend
Maximum
Screw Size*
Screw Size*
Size
1-1/4 in.
1-7/8 in.
(32 mm)
(48 mm)
1-1/2 in.
2 in.
(38 mm)
(51 mm)
1-3/4 in.
2-1/4 in.
(45 mm)
(57 mm)
2 in.
2-1/2 in.
(51 mm)
(64 mm)
2-1/4in.
2-3/4 in.
(57 mm)
(70 mm)
2-1/4in.
2-3/4 in.
(57 mm)
(70 mm)
2 .6 .2 Opening Depth: 2 to 4 in .
(51 to 102 mm)
For a roof or wall thickness from 2 in. (51 mm) to 4 in.
(102 mm), use a 4-1/4 in. (108 mm) trim garnish and
adjust the size according to the table below.
To request the correct trim garnish, contact
I
your local Dometic service partner or dealer
or the Dometic Customer Support Center at
800-544-4881.
Roof
Recommend
or Wall
Trim Garnish
Trim Garnish
Thickness
Size
2 in.
2 in.
1-3/4 in.
(51 mm)
(51 mm)
(45 mm)
2-1/4 in.
2-1/4 in.
2 in.
(57 mm)
(57 mm)
(51 mm)
2-1/2 in.
2-1/2 in.
2-1/4 in.
(64 mm)
(64 mm)
(57 mm)
2-3/4 in.
2-3/4 in.
2-1/2 in.
(70 mm)
(70 mm)
(64 mm)
3 in.
3 in.
2-3/4 in.
(76 mm)
(76 mm)
(70 mm)
3-1/4 in.
3-1/4 in.
3 in.
(83 mm)
(83 mm)
(76 mm)
3-1/2 in.
3-1/2 in.
3-1/4 in.
(89 mm)
(89 mm)
(83 mm)
3-3/4 in.
3-3/4 in.
3-1/2 in.
(95 mm)
(95 mm)
(89 mm)
4 in.
4 in.
3-3/4 in.
(102 mm)
(102 mm)
(95 mm)
*These recommended screw sizes are for a clamp-fan
installation only.
Fan-Tastic Vent Fan
Minimum
Recommend
Maximum
Screw Size*
Screw Size*
Size
2-1/2 in.
3 in.
(64 mm)
(76 mm)
2-3/4 in.
3-1/4 in.
(70 mm)
(83 mm)
3 in.
3-1/2 in.
(76 mm)
(89 mm)
3-1/4 in.
3-3/4 in.
(83 mm)
(95 mm)
3-1/2 in.
4 in.
(89 mm)
(102 mm)
3-3/4 in.
4-1/4 in.
(95 mm)
(108 mm)
4 in.
4-1/2 in.
(102 mm)
(114 mm)
4-1/4 in.
4-3/4 in.
(108 mm)
(121 mm)
4-1/2 in.
5 in.
(114 mm)
(127 mm)