Assembly
Replacing/Inserting the Saw Blade
Before any work on the machine itself, pull
the mains plug.
When mounting the saw blade, wear protec-
tive gloves. Danger of injury when touching
the saw blade.
When changing the saw blade, take care
that the saw blade holder is free of material
residue, e. g. wood or metal shavings.
Selecting a Saw Blade
Use only saw blades suitable for the material be-
ing worked.
An overview of recommended saw blades can
be found at the beginning of these operating in-
structions. Use only saw blades with single-nose
shank. The saw blade should not be longer than
required for the intended cut.
Use a thin saw blade for narrow curve cuts.
Inserting the Saw Blade (see figure A)
Turn the SDS lever 3 approx. 180° in clockwise
direction to the stop and insert the saw blade 1
behind the clamping plate 4. Release the SDS le-
ver 3, checking at the same time that the pin on
the saw blade holder is engaged into the inser-
tion hole of the saw blade.
Check the tight seating of the saw blade. A
loose saw blade can fall out and lead to inju-
ries.
For certain work, the saw blade 1 can also be
turned through 180° (with the teeth pointed up-
wards) and re-inserted again.
Ejecting the Saw Blade (see figure A)
Turn the SDS lever 3 by approx. 180° in clock-
wise direction and pull out the saw blade 1.
Bosch Power Tools
Dust/Chip Extraction
Dusts from materials such as lead-containing
coatings, some wood types, minerals and
metal can be harmful to one's health. Touch-
ing or breathing-in the dusts can cause aller-
gic reactions and/or lead to respiratory infec-
tions of the user or bystanders.
Certain dusts, such as oak or beech dust, are
considered as carcinogenic, especially in
connection with wood-treatment additives
(chromate, wood preservative). Materials
containing asbestos may only be worked by
specialists.
– Provide for good ventilation of the work-
ing place.
– It is recommended to wear a P2 filter-
class respirator.
Observe the relevant regulations in your
country for the materials to be worked.
Operation
Operating Modes
Before any work on the machine itself, pull
the mains plug.
Turning the Rotating Collar (see figure B)
For certain jobs, the rotating collar 7 can be
turned. Push the release button for the collar 8
to the rear and turn the rotating collar 7 to the
required position.
The position of the rotating collar 7 can be
locked in 90° steps. For this, turn the rotating
collar 7 until the mark on the rotating collar 7 is
in alignment with the mark on the release but-
ton 8. Push the release button for the collar 8 to-
ward the front.
Pivoting Footplate (see figure C)
Due to its movability, the adjustable footplate 2
adapts to the required angular position of the
surface.