I.2.3.6
Setting the v entilation
Press the F AN key repeatedl y to set one of the three
speeds availabl e or acti vate the AUTO func tion to
set it automaticall y acc ording to the difference
between the Set-poi nt and room temperatures.
The sel ected speed and operati ng mode appear on
the display.
The CONT function is acti vated by pressing this key:
ventilati on is forced to the minimum speed when the
set temperature value is reac hed. The continuous
ventilati on s ymbol appears on the display. The
functi on is onl y acti ve in the MPCV models ( with
val ve).
I.2.3.7
Setting the desired temperature
Press these keys to increase or decreas e the
desired temperatur e value. In the FULL AUTO
mode, press thes e keys to var y the preset
temperature value by ±2°C. The selec ted
temperature value appears on the display.
Desired temperature value s etti ng in the COOL,
Variation in the desired temperature value in the
I.2.3.8
Setting the Timer
Press these keys to set the unit s witc h-on and/or
switch-off ti me.
ON or OFF blinks on the dis play.
The TIMER functi on is repeated ever y 24 hours until
it is deacti vated.
Press this key to adjust the s witch-on or s witch- off
time. The time increases or decreas es by 10
minutes ever y ti me the key is pressed.
Once the desired s witch-on or switc h-off time is
reached, c onfir m the s etting by pressing the SET
key.
The C ANC key deac tivates the TIMER func tions,
which are s elected by pressing the Tim er ON or
Timer OFF keys.
Once the switc h-on and s witch- off times are
set the c urrent time appears on the display
together with ON and/or OFF, thereby
indicating that the ti mer has been s et.
Automatic speed control
Minimum speed
Medium speed
Maxi mum speed
Continuous ventilation
DRY and HEAT modes.
FULL AUTO mode.
Switc h-on time
Switc h-off time
I.2.3.9
Setting the Sleep mode
The "night-ti me air conditioni ng" SLEEP function is
set by pressing this key. The fan is forced to the
minimum speed, the brightness of the LEDs is
reduced and the oper ating temperature val ues are
opti mised (the COOL/DRY s et-point is i ncreas ed by
1°C, whereas the HEAT s et-poi nt is decreased by
1°C). The dur ation will be increased by 1 hour, from
a mi nimum of 1 to a maximum of 9, ever y ti me the
key is press ed. The Sleep s ymbol and the duration
of the func tion will appear on the display.
Simpl y press the SLEEP key once again to
deac tivate the functi on.
Once the set time el apses , the SLEEP func tion is
deac tivated and the functi on together with its
duration disappear from on the display.
SLEEP function acti vated for 8 hours.
I.2.3.10 Setting the clock
Press the Tim er UP and Tim er DOW N
keys simultaneousl y for 5 sec onds and the
time on the displ ay will start to blink,
thereby allowing it to be s et.
The ti me c an be increas ed or decreas ed
by 1 minute eac h ti me they are press ed, or
quickly if press ed for at least two sec onds.
The set ti me is c onfirmed by pressing this key.
I.2.3.11 Blocking the keypad
Press the C ANC key for 5 s econds to bloc k the
keypad on the r emote control, thereby
preventing it from being mis used (children,
etc.). Only ON/OFF is acti ve. Press the C ANC
key once again for 5 s econds to rel ease the
lock function.
I.2.3.12 Selecting the room probe
The room temperatur e can be detected by the pr obe inside the
control panel or the probe fixed to the unit. The s election is made by
positioning dip-s witch 6 of the CMS board correctl y (di p6 = ON -
adjusted from the pr obe inside the rec essed panel).