Cross Line Laser
Applications
• Floor and wall tiles
• Wallpaper
• Finish carpentry
• Door and window frames
• Drop ceilings
• Interior decoration...
O O v v e e r r v v i i e e w w
Control panel
Laser output
Battery compartment
window
(under rubber over-mold)
A
1/4" x 20 tripod mount
B
Specifications
Recommended use
100 ft. (30 m)
Leveling accuracy
± 1/8" @ 30' (3 mm / 9 m)
Self-leveling range
± 4°
Laser beams
Highly visible 635 nm, Class 2 M
Cross line
130° horizontal and vertical fan angles
Manual mode
Lock line to match any angle
between two points
Power
3 AA batteries 1,5 V
Working temperature 23° to 104° F (-5° to +40°C)
Tripod mount
1/4'' x 20 thread
Size
3-1/2" x 3-1/3" x 2-1/2" (9 x 8,4 x 6,2 cm)
Weight
12 oz (340g)
Includes
Belt carrying pouch, batteries
Battery life
25 hrs. continuous use (1 line on),
12.5 hrs. continuous use (2 lines on)
Leveling
Self-leveling
We recommend checking the instrument's calibration before
initial use; then periodically to ensure proper reference.
Checking the horizontal line front to back
1. Set up the CL30 about 6" (15 cm) away from a wall
(Surface 1) and 12-15 ft. (4-5m) from another wall (Surface 2).
2. Turn it on in cross line mode. Be sure it's self-leveling.
3. Carefully mark the center where the lines cross on Surface
1. This is A1.
User Manual
4. Rotate the laser 180° and mark the center where the lines
cross on Surface 2 (this is B1).
5. Right illustration: Move the laser 6" away from Surface 2 and
mark the center where the lines cross on Surface 2 (this is B2).
6. Rotate the laser 180° and mark the center where the lines
cross on Surface 1 (this is A2).
7. Measure the distance between A1 and A2, and also
between B1 and B2. If the distances are the same, the laser is
in calibration. If the difference between the two sets of marks is
greater than 1/8" (3 mm), the laser is out of calibration.
Checking the horizontal line side to side
1. Set the instrument up approximately 8' (2.5m) from a wall that
is at least 16' (5m) long.
2. Project the laser cross 1' (30cm) from one corner (1). Mark
point (2) along the horizontal laser line 8' (2.5m) from the
intersection of the laser cross.
3. Rotate the instrument so that the laser cross (3) is projected at
the wall 15' (4.6m) away from the first laser cross point (1).
4. The deviation of the horizontal laser line from the point (2)
marked previously should not be further apart than 1/8" or 3 mm.
This is a precision instrument which must be handled with
care. Avoid shock and vibrations. Keep the laser and aper-
ture lens clean and dry. Use a soft cloth and glass cleaner to
clean them. Remove batteries before long-term storage.
Calibration control
Care and Handling
Control panel
1. ON button. Press to cycle through A-E:
a. Level (horizontal fan line)
b. Plumb (vertical fan line)
c. Cross line (horizontal and vertical)
d. Locked cross line (manual mode)
e. Off
2. LED for laser mode, low battery
2
USING THE CL30 The CL30 cross line laser uses a pendu-
lum mechanism for self-leveling. In order for the unit to auto-
matically level, it must be set up within 4 degrees of level.
LED indications
• The LED is green in automatic mode.
• If the LED is red and the lasers blink in level or plumb mode,
the laser is out of leveling range.
• If the LED is green and the lasers blink in cross line mode,
the laser is out of leveling range.
• The LED is red in manual mode.
• If the LED blinks, the batteries are low.
Safety
Do not stare directly at the beam.
A
Do not set up the laser at eye level.
B
COMPLIES WITH 21 CFR
1040.10 AND 1040.11
EXCEPT FOR DEVIATIONS
PURSUANT TO LASER NOTICE NO. 50
DATED JULY 26, 2001 AGATEC, 2202 Redmond Road Jacksonville, AR 72076
Warranty
The CL30 laser is guaranteed to be free of manufacturing
defects for a period of 2 years (1 year in North America).
Any abnormal usage or if the instrument has been subjected
to shock will void this warranty. Under no circumstances will
the liability of the manufacturer exceed the cost of repairing
or replacing the instrument. Disassembling the instrument by
other than qualified and certified technicians will void this
warranty. Specifications are subject to change without notice.
Information
For more information, please contact:
For US, Canada and
For all other countries
Latin America
AGATEC Construction Lasers
21 boulevard Littré
2202 Redmond Rd.,
78600 Le Mesnil-le-Roi
Jacksonville, AR 72076 - USA
Tel. (800) 643-9696
Tél. +33 (0) 1 34 93 35 80
(501) 982-4433
Fax +33 (0) 1 34 93 35 89
Fax (501) 982-0880
sales@agatec.com
sales@agatec-na.com
www.agatec.com
www.agatec-na.com
1
AGATEC
France

Publicité

loading

Sommaire des Matières pour Agatec CL30

  • Page 1 Cross line (horizontal and vertical) Checking the horizontal line front to back d. Locked cross line (manual mode) 1. Set up the CL30 about 6” (15 cm) away from a wall e. Off (Surface 1) and 12-15 ft. (4-5m) from another wall (Surface 2).
  • Page 2 Mode vertical Vérification du niveau horizontal d’avant en arrière c. Mode croix 1. Positionner votre CL30 à 15 cm d’un mur (Surface 1) et à 4-5 m d. Utilisation en mode manuel (hors calage d’un autre mur (Surface 2).