PROGRAMMING
SELECT THE PHASE AND WIRING TYPE
NOTE: DO NOT activate the operator until the following steps have
been completed.
1-PHASE:
The new logic control board is shipped with the jumper in the
1-phase position.
3-PHASE:
1. Set the jumper for motor direction.
2. Turn the SELECTOR DIAL to PROG (programming).
3. Move the PHASE jumper from the 1-Phase position to the
3-Phase position.
4. Turn the SELECTOR DIAL to the desired wiring type.
For a detailed description of wiring type operating modes, see
installation manual for the operator.
Activate the operator to test function.
The following need to be programmed for the new logic control board.
• All remote controls (on board receiver only)
®
• MyQ
setup (optional)
• Maintenance Alert System (MAS)
• Timer-to-Close
• Open Mid Stop
• Car Dealer Mode
• Maximum Run Timer (MRT)
• Pre-warning timer when the TLSCARD option card is used
(see TLSCARD manual for instructions)
INTRODUCTION TO PROGRAMMING
Many programmable functions require that a LiftMaster
Entrapment Protection (LMEP) device be installed in order to
function.
Before programming the logic control board, set the operator's
open and close limits. LEDs on the logic control board are
provided to assist setting the limits. As each limit is activated the
corresponding LED will light up. The abbreviations are Open Limit
Switch (OLS), Close Limit Switch (CLS) and Sensing Limit Switch
(SLS). Refer to the installation manual for limit switch adjustment
instructions.
When power is applied to the operator, the following LED's will
illuminate: STOP, CLOSE, OPEN, LMEP, 24Vac, RADIO, DATA,
TIMER ENABLE, OLS MID, SLS, CLS, and MAS. Once the power
up process is completed (approximately 2-3 seconds) only the
appropriate LED's will continue to be lit (i.e., STOP, 24Vdc, limit
LED(s) if limit(s) is activated).
NOTE: When the power up process has completed, the MAS LED
will blink a code indicating the version of firmware. If the selector
dial is in the DIAG, OPTN, or PROG position, the MAS will not
provide this code. After the code has been provided the MAS LED
will go out.
LOGIC CONTROL BOARD PUSH BUTTONS (OPEN, CLOSE, STOP)
Open, Close and Stop buttons are mounted directly on the logic
control board making it easy to program as well as have door
control at the electrical box.
Either the stop control or a jumper MUST be wired between
terminals 4 and 5 for the on board push buttons to function.
5
Set to PROG
Phase jumper
Select wiring type

Publicité

loading