AERMEC WRL 180 Manuel Technique page 23

Table des Matières

Publicité

WRL600X°°°°°°°°
13.13. WRL600X°°°°°°°° FONCTIONNEMENT À CHAUD
25
Ph
Pe
C.O.P.
[kW]
-8
113.62 22.87
4.97 111.54 25.36
-6
123.70 23.13
5.35 121.45 25.57
-4
133.38 23.36
5.71 130.97 25.76
-3
138.09 23.47
5.89 135.60 25.85
-2
142.74 23.57
6.06 140.17 25.94
0
151.87 23.76
6.39 149.14 26.11
2
160.84 23.95
6.72 157.96 26.26
4
169.73 24.12
7.04 166.71 26.41
5
174.18 24.21
7.20 171.09 26.49
6
178.64 24.29
7.35 175.47 26.56
7
183.11 24.37
7.51 179.88 26.63
8
187.62 24.46
7.67 184.32 26.71
10 196.78 24.63
7.99 193.34 26.87
12
-
-
-
14
-
-
-
16
-
-
-
18
-
-
-
13.14. WRL600X°°°°°°°° FONCTIONNEMENT À FROID
25
Pc
Pe
EER
[kW]
-8
91.26 22.76
4.01
-6
101.41 23.02
4.41
-4
111.15 23.25
4.78 106.71 25.66
-3
115.89 23.36
4.96 111.40 25.75
-2
120.55 23.46
5.14 116.03 25.84
0
129.67 23.66
5.48 125.11 26.01
2
138.56 23.84
5.81 134.01 26.16
4
147.30 24.02
6.13 142.77 26.31
5
151.63 24.10
6.29 147.13 26.39
6
155.94 24.19
6.45 151.48 26.46
7
160.24 24.27
6.60 155.82 26.53
8
164.53 24.36
6.76 160.18 26.61
10 173.15 24.53
7.06 168.93 26.76
12
-
-
-
14
-
-
-
16
-
-
-
18
-
-
-
ATTENTION !
Les données de Ppuissance de rendement et absorbée de ces tableaux se réfèrent aux rendements et aux absorptions des unités WRL sans
prendre en considération les 'cotes de la pompe UNI EN 14511: 2008 (comme exigé par Eurovent).
LEGENDE
Rendement thermique
Ph
Rendement frigorifique
Pc
Puissance absorbée
Pe
TEMPERATURE DE L'EAU EN SORTIE DU CONDENSEUR ºC
30
35
Ph
Pe
C.O.P.
Ph
Pe
[kW]
[kW]
4.40 109.76 28.27
4.75 119.43 28.45
5.08 128.70 28.60
5.24 133.22 28.68
5.40 137.67 28.75
5.71 146.40 28.88
6.02 154.99 29.01
6.31 163.51 29.13
6.46 167.76 29.19
6.61 172.04 29.26
6.75 176.33 29.32
6.90 180.66 29.39
7.20 189.46 29.53
202.60 27.03
7.50 198.51 29.68
212.20 27.21
7.80 207.90 29.84
-
-
-
217.70 30.03
-
-
-
228.00 30.24
TEMPERATURE DE L'EAU EN SORTIE DU CONDENSEUR ºC
30
35
Pc
Pe
EER
Pc
Pe
[kW]
[kW]
87.07 25.25
3.45
82.49 28.16
97.07 25.47
3.81
92.20 28.34
4.16 101.59 28.50
4.33 106.18 28.57
4.49 110.70 28.64
4.81 119.60 28.77
5.12 128.35 28.90
5.43 137.01 29.02
5.58 141.33 29.09
5.72 145.64 29.15
5.87 150.42 29.25
6.02 154.31 29.28
6.31 163.06 29.41
177.81 26.93
6.60 171.96 29.56
186.86 27.10
6.89 181.08 29.73
-
-
-
190.47 29.91
-
-
-
200.19 30.12
∆T DIFFÉRENTS DU NOMINAL (∆T 5)
A L'EVAPORATEUR
Rendement frigorifique
Puissance absorbée
Rendement thermique
AL CONDENSEUR
Rendement frigorifique
Puissance absorbée
Rendement thermique
40
C.O.P.
Ph
Pe
C.O.P.
Ph
[kW]
3.88 108.03 31.52
3.43
4.20 117.37 31.65
3.71 114.99 35.08
4.50 126.31 31.77
3.98 123.53 35.15
4.65 130.67 31.82
4.11 127.68 35.19
4.79 134.95 31.88
4.23 131.76 35.22
5.07 143.37 31.98
4.48 139.77 35.29
5.34 151.64 32.07
4.73 147.64 35.35
5.61 159.84 32.17
4.97 155.45 35.42
5.75 163.95 32.22
5.09 159.99 35.68
5.88 168.06 32.27
5.21 163.28 35.50
6.01 172.21 32.33
5.33 167.22 35.54
6.15 176.38 32.38
5.45 171.20 35.59
6.42 184.88 32.50
5.69 179.31 35.69
6.69 193.63 32.64
5.93 187.68 35.81
6.97 202.72 32.79
6.18 196.39 35.95
7.25 212.23 32.97
6.44 205.53 36.12
7.54 222.24 33.17
6.70 215.16 36.31
40
EER
Pc
Pe
EER
Pc
[kW]
2.93
77.55 31.40
2.47
3.25
86.84 31.53
2.75
81.03 34.94
3.56
95.84 31.65
3.03
89.49 35.02
3.72 100.24 31.70
3.16
93.65 35.05
3.87 104.60 31.76
3.29
97.76 35.09
4.16 113.18 31.86
3.55 105.88 35.15
4.44 121.65 31.95
3.81 113.92 35.22
4.72 130.06 32.05
4.06 121.94 35.28
4.86 134.26 32.10
4.18 125.96 35.32
5.00 138.47 32.15
4.31 130.00 35.36
5.14 142.70 32.20
4.43 134.07 35.40
5.27 146.96 32.26
4.56 138.17 35.45
5.54 155.56 32.38
4.80 146.49 35.55
5.82 164.36 32.51
5.06 155.04 35.67
6.09 173.40 32.67
5.31 163.87 35.81
6.37 182.76 32.84
5.56 173.04 35.97
6.65 192.47 33.04
5.82 182.61 36.17
3
5
8
10
0,99
1
1,02
1,03
0,99
1
1,01
1,02
0,99
1
1,02
1,03
5
10
15
-
-
1
1,01
1,02
-
1
0,99
0,98
les variations sont négligeables
45
50
Pe
C.O.P.
Ph
Pe
[kW]
[kW]
-
-
-
-
-
3.28
-
-
3.51 120.08 38.65
3.63 123.98 38.66
3.74 127.82 38.68
3.96 135.34 38.71
4.18 142.73 38.74
4.39 150.06 38.78
4.48 153.72 38.80
4.60 157.41 38.83
4.71 161.12 38.86
4.81 164.86 38.89
5.02 172.50 38.97
5.24 180.40 39.08
5.46 188.65 39.20
5.69 197.32 39.36
5.93 206.50 39.54
45
50
Pe
EER
Pc
Pe
[kW]
[kW]
-
-
-
-
-
2.32
-
-
2.56
82.59 38.49
2.67
86.42 38.51
2.79
90.22 38.52
3.01
97.74 38.55
3.23 105.22 38.59
3.46 112.71 38.62
3.57 116.48 38.65
3.68 120.27 38.67
3.79 124.11 38.70
3.90 127.98 38.74
4.12 135.88 38.82
4.35 144.03 38.92
4.58 152.51 39.05
4.81 161.36 39.20
5.05 170.65 39.39
FACTEUR D'ENCRASSEMENT [K*M
0,00001
Puissance frigorifique
Puissance absorbée
Puissance thermique
Puissance absorbée
55
C.O.P.
Ph
Pe
C.O.P.
[kW]
-
-
-
-
-
-
-
-
3.11
-
-
-
3.21
-
-
-
3.30
-
-
-
3.50 129.81 42.13
3.08
3.68 136.63 42.12
3.24
3.87 143.39 42.13
3.40
3.96 146.78 42.14
3.48
4.05 150.18 42.15
3.56
4.15 153.61 42.17
3.64
4.24 157.08 42.19
3.72
4.43 164.16 42.25
3.89
4.62 171.52 42.33
4.05
4.81 179.22 42.44
4.22
5.01 187.35 42.59
4.40
5.22 195.99 42.76
4.58
55
EER
Pc
Pe
EER
[kW]
-
-
-
-
-
-
-
-
2.15
-
-
-
2.24
-
-
-
2.34
-
-
-
2.54
88.80 41.96
2.12
2.73
95.57 41.96
2.28
2.92 102.39 41.97
2.44
3.01 105.84 41.98
2.52
3.11 109.32 41.99
2.60
3.21 112.85 42.01
2.69
3.30 116.43 42.03
2.77
3.50 123.76 42.09
2.94
3.70 131.38 42.17
3.12
3.91 139.36 42.29
3.30
4.12 147.75 42.43
3.48
4.33 156.62 42.61
3.68
]/[W]
2
0,00002
0,00005
1
0,99
0,98
1
1
1
1
1
0,99
1
1
1,02
23

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Wrl 200Wrl 300Wrl 400Wrl 500Wrl 550Wrl 600 ... Afficher tout

Table des Matières