12. Fault indicator
• CU conveyor belt: The fault indicator is lit and the belt stops. The reason could be overloading
of the motor, a fault in the frequency converter or activation of the emergency stop. The fault
indicator is not lit if the conveyor belt's 240/110 (UK) Volt power supply fails.
• CCU conveyor belt: The fault indicator is lit and the belt stops. The reason could be overloading
of the motor, a fault in the frequency converter or activation of the emergency stop. The fault
indicator is not lit if the conveyor belt's 240/110 (UK) Volt power supply fails.
• Series connection: If a drum motor in the conveyor belt is overloaded, the control will
automatically stop the entire series connection, and the fault indicator on the unit with the
overloaded motor is lit.
• Series connection: In the event of a frequency converter fault, the control will automatically stop
the entire series connection, and the fault indicator on the unit with a defective internal control is
lit.
• Series connection: If the 240/110 (UK) Volt power supply to a unit in the series connection fails, the
entire line will automatically stop, and the fault indicators on all other units are lit.
13. Spare parts
A complete list of spare parts is available on our website www.baron-mixer.com.
14. Technical data
Technical data
Belt length (mm)
Total length (mm)
Belt width (mm)
Total width (mm)
Heigth (mm)
Weight (kilo)
Drum motor (kW)
Drum motor (volt)
Max tension (kilo)
Belt speed (cm/s)
Power supply (volt)
Power supply (volt - UK)
15. Warranty
The warranty becomes null and void if:
• the conveyor belt is used for other purposes or in other ways than described in this manual,
• a high-pressure cleaner is aimed directly at the conveyor belt's control box.
CU2500
CCU3300
2500
3300
2800
3600
340
340
455
455
250
250
61
71
0,55
0,55
3x240
3x240
200
200
20 - 80
20 - 80
240
240
110
110
CU4500
CU6000
4500
6000
4800
6300
340
340
455
455
250
250
87
103
0,55
0,55
3x240
3x240
200
200
20 - 80
20 - 80
240
240
110
110
UK
CCU4500
CCU6000
4500
6000
4800
63000
340
340
455
455
250
250
87
103
0,55
0,55
3x240
3x240
200
200
20 - 80
20 - 80
240
240
110
110