Technical Data - oventrop Regudis W-HTU Duo Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4 Technical data

4.1 Performance data
Size:
Max. operating pressure p
primary side
secondary side
(diaphragm safety valve
Max. operating temperature t
(Heating water – supply)
Min. differential pressure
supply:
Potable water circuit (secondary side):
Min. cold water pressure
without flow limiter
with flow limiter
Min. differential pressure supply:
Draw off temperature t
draw off
Min. flow temperature:
Connections:
Performance range 1
Nominal draw off quantity (PHW): 12l/min
Draw off capacity at dT 35K:
Performance range 2
Nominal draw off quantity (PHW): 15l/min
Draw off capacity at dT 35K:
Performance range 3
Nominal draw off quantity (PHW): 17l/min
Draw off capacity at dT 35K:
Fluid primary side:
Fluid secondary side:
Heating circuit (secondary side):
Max. operating pressure:
Diaphragm safety valve:
Max. flow temperature:
Regulator control range:
Volume diaphragm
expansion tank:
Heat exchanger:
The performance dates are determined by the fixed
given values in the primary circuit (90/ 70 °C) and the
secondary circuit (55/ 70 °C).
Pump:
Fluid primary side:
Fluid secondary side:
System volume with connected heating circuit:
Max. system volume V
max
tank (volume 3 l) depending on the flow temperature.
When cold, the water volume of the expansion tank
amounts to 0.6 l (corresponds to 20 % of the tank
volume (3 l), according to DIN 12828 appendix D.2).
20
DN 20
:
s
16 bar (PN 16)
10 bar
3 bar)
:
90 °C
s
300 mbar
2.0 bar
2.5 bar
300 mbar
:
40-70 °C
t
+ 15K
draw off
3
G
collar nut,
4
flat sealing
29 KW
36 KW
42KW
heating water
Potable water
3 bar
3 bar
70 °C
40 ° - 70 °C
3 l
13 kW (14 plates)
Wilo-Yonos PARA
RS 15/6 RKA 130
Heating water
Heating water
related to the expansion
Flow
V
max
temperature
30 °C
220 l
35 °C
150 l
40 °C
115 l
45 °C
90 l
50 °C
80 l
55 °C
60 l
60 °C
55 l
The values indicated in the table are approximate
values. In particular cases, significant deviations are
possible.
NOTICE
When used in an underfloor heating system, it is
recommended to replace the temperature
controller with a lower control range temperature
controller (OV item no. 1142861, control range
20- 50 °C).
With a heat demand of approx. 13 kW in the heating
circuit of the dwelling, the floor area should be limited
to 100 m² (calculation based on a laying distance of
150 mm).
Fluid: Non-aggressive fluids (e.g. water and suitable
water and glycol mixtures according to VDI 2035). Not
suitable for steam, oily and aggressive fluids.
DANGER
Suitable measures (e.g. safety valves) have to be
taken to ensure that the maximum operating
pressures and maximum and minimum operating
temperatures are not exceeded or undercut.
If necessary, provide an electric sensor attached
to the pipe (safety temperature limiter OV item
no. 1143000) to protect the surface heating
circuit from unacceptably high temperatures.
NOTICE
The operating instructions of the pump
manufacturer must be observed
4.2 Materials
Plate heat exchanger
Pipes
Valves and fittings
Seals
Base plate
Flow
V
max
temperature
65 °C
50 l
70 °C
40 l
75 °C
35 l
80 °C
30 l
85 °C
28 l
90 °C
25 l
Stainless steel 1.4401/
brazed copper or nickel
Stainless steel 1.4404
Brass / brass resistant to
dezincification
EPDM / PTFE
Steel, galvanised