Gas conversions from Natural gas to LP gas or from LP gas to
Natural gas must be done by a qualified installer.
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.

LP Gas Conversion

WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip bracket to rear range foot.
Reconnect the anti-tip bracket, if the range is moved.
Failure to follow these instructions can result in death
or serious burns to children and adults.
1. Turn manual shutoff valve to the closed position.
2. Unplug range or disconnect power.
A
A. To range
B. Shutoff valve (closed position)
C. Gas supply line
18
All manuals and user guides at all-guides.com

GAS CONVERSIONS

B
C
To Convert Gas Pressure Regulator
1. Locate gas pressure regulator at the rear of the range.
A. Gas pressure regulator
IMPORTANT: Do not remove the gas pressure regulator.
2. Unscrew the hex-shaped regulator cap from the regulator
and remove the regulator pin.
A. Regulator pin
B. Regulator cap
3. Flip the regulator pin over and snap pin firmly into place.
A
A. Natural gas position
B. LP gas position
4. Screw the hex-shaped regulator cap securely back into
place. Do not overtighten.
A
A
B
B