STANDALONE KEYPAD ACCESS CONTROL - NEXA
SAFETY PRECAUTIONS
- Install or modify the equipment, without the power connected.
- The installation and handling of this equipment must be performed by authorised personnel.
- The entire installation must be at least
40 cm.
- In the power supply unit:
wDo not
use excessive force when tightening
w Install the transformer in a dry and protected
w A
void
to place it near to heating sources, in dusty locations or smoky enviroments.
w Do not block ventilation holes of the unit so that air can circulate freely.
w To
avoid damage, the
transformer
has o
w T prevent electric shock, do not remove the protection cover or handle the wiring connected to the terminals.
o
( )
SYSTEM CHARACTERISTICS
*
- Standalone numeric keypad access control (backlit keypad).
- Power 12Vac or 18-24Vdc.
- 2 potential-free relay outputs (NO, C, NC) and digital panic output with 999 user codes.
- 4, 5 or 6 digit programmable codes.
- Possibility of using the same user code for the different relays and digital panic output.
- Relays 1 and 2 with three potential-free contacts (NO, C, NC), configurable as stable or impulse mode
(maximum load: 18Vac/1A 18VA or 24Vdc/0,75A 18W).
- Impulse mode activation time programmable from 1 to 99 seconds for each relay & digital panic output.
- Leds on the front to indicate operating status and internal beeper for reproducing tones & 'tamper' alarm.
( )
ACCESS CONTROL INSTALLATION
*
1850
1650
1450
Hole dimensions for embedding box NCEV-90CS:
99(W) x 132,5(H) x 56,5(D) mm.
MODULE DESCRIPTION
( )
*
( ) Module description:
*
The wiring terminals are located at the back of the module and
correspond to the following connections:
( ) For more information see user manual "TKIT N4301 ML (code 50123637)".
*
https://doc.golmar.es/search/manual/50123637
away from any
other wiring.
the
connector screws
.
place without risk of drip or water projections
t be firmly
fixed
.
Embedding box.
Frame.
Panel.
~, ~ :
power supply.
NA1 :
normally open output relay
C1 :
com
mon
rel
ay
1.
NC1 :
normally closed output relay
NA2 :
normally open output relay
C2 :
com
mon
rel
ay
2.
NC2 :
normally closed output relay
P :
panic output
.
_
:
negativ . e
_
PL1 :
input for external relay 1 push button
PL2 :
input for external relay 2 push button
2
STANDALONE KEYPAD ACCESS CONTROL - NEXA
Coming from previous page.
( ) JP1 jumper description:
*
It is located at the right of the terminal block.
JP1
.
( ) Self-testing led description:
*
Standby
Programming
Confirm field
mode
Confirm sequence
( )
(EXAMPLE) BASIC PROGRAMMING AND OPERATION
*
- Step 1: Programming mode entry.
Press the key button three times and then enter secret administrator code "2718", 5 quick beeps
will be heard and the red led will slow blink confirming the module is in programming mode.
Closing
heads.
- Step 2: User programming (user code).
In programming mode, press the next "example" sequence to set the user 1 (001) with an user code
(1234) and the relay 1 to activate. To exit programming mode, press the 'C' button.
Sequence Field
1 ( )
Outputs: "01" (activates the relay 1) "02" (activates the relay 2) "03" (activates the relays 1 & 2).
- Step 3: Programmed operation mode.
With the module in standby mode (red led in ON).
1.
Check that the user code (programmed in the step 2) activates the selected relay.
1.
2.
1.
- Change user code.
With the module in standby mode (red led in ON). Press the next sequence:
.
.
Continue.
( ) For more information see user manual "TKIT N4301 ML (code 50123637)".
*
https://doc.golmar.es/search/manual/50123637
( ) SW1 microswitch description:
*
It is located at the left side of the module.
Normal operation, alarm not
activated.
Tamper alarm mode activated In
.
this mode, the module's keypad
operation and external buttons are
disabled.
( ) 1 Factory default.
( ) Beep description:
*
Operation
Red Led
Green Led
Normal
On
Off
Correct code
On
On (1 se
cond
)
Wrong code
4 quick blinks
Off
Normal
Slow blink
Off
Slow blink
2 quick blinks
Slow blink
4 quick blinks
Key button + key + key + administrator code
2
7
:
+
memory position
+
user code
1
0 0 1
1 2 3 4
/
Key +
user code
1
2
3
Key + key + current user code + key + new user code + key
3
It enables the "especial
instal
ler pin code to the
"
( ) 1
assigned factory code.
Standalone access control
(placed to OFF position).
Operation
Dura i n
t o
Programming
5 quick beeps
Confirm field
2 quick beeps
Confirm se uenc
q
e
4 quick beeps
Error
1
long beep
(1 se .)
c
Key press
1 quick beep
Alarm activated
1 constant beep
1
8
+
outputs
+
key
.
1 ( )
0
1
/
4
Continue.