- Place the plastic flanges in the positions described in fig. no. 4
with numbers 1 and 2 using the M5 screws supplied in the bag.
Next, install the flange tabs on the sides using the M6 counter-
sunk screws, which are also supplied in the bag of nuts and
screws.
Fig. 4
- Place the fluorescent tubes in position no. 1, clipping
them to the flanges.
- Place the reactance tube in position no. 2, also clip-
ping it to the flanges.
- Fasten the watertight box in position no. 3 with Velcro.

7. PLUMBING

You should only install the connections for the taps purchased to
fill the bathtub, according to their own installation instructions.
For the drain to work properly, place the height-adjustment stud
in a position that allows the drain to close in a watertight position
and to open easily. Simply place this stud in an intermediate posi-
tion between the maximum top and bottom positions and check
that it works properly. To adjust this stud, simply turn it to the
desired position and fix it in this position by fully turning the nut.
The positions of these parts can be seen in Fig. 5.
Fig. 5

8. ELECTRICAL INSTALLATION

8.1. PROTECTION AREA

The electrical installation for the bathtub must be compliant with
current legislation governing low voltage. For this, it is important
to bear in mind that four protection volumes need to be estab-
lished where the bathtub is to be installed, defined as shown in
the following diagram. (Figure 6)
Fig. 6
The connections cannot be made in volume 0
N.B.:
- Volume 0 is defined by the inside volume of the bathtub.
- Volume 1 is defined by the upper plane outside volume 0 and
the horizontal plane at a height of 2.25 m above the floor.
- Volume 2 is defined by the vertical area outside volume 1 and
the vertical area in parallel with this 0.6 m from volume 1 up to a
height of 2.25 m above the floor.
- Volume 3 is defined by the vertical plane outside volume 2 and
the vertical plane in parallel with this 2.40 m outside volume 2 up
to a height of 2.25 m above the floor.
Underneath the bathtub is considered as volume 3, as long as the
watertight connections are more than 20 cm from the floor.

8.2. POWER CONNECTION

A cable with three conductors with a cross-section of 1.5 mm²
H05VV-F comes out of the watertight box and must be con-
nected to the mains.
The 230 V power line for the lighting kit must have its own
switch.
You must bear the following in mind when making this connec-
tion:
- The bathtub power supply must be permanently connected to a
fixed electrical conduit.
- You must use the power cable supplied with the kit or another
cable of the same type with a diameter identical to the supplied
cable and which also complies with current low-voltage regula-
tions. In the event of fully replacing the supplied cable, remember
that the yellow/green earth wire must be at least 40 mm longer
than the live and neutral wires. This guarantees that, in the case
of a pull, the last wire to come loose from the strip will be the
earth wire and electrical protection will not be lost.
- If the power connection is made below the bathtub, it must be
12